MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2021.04.007

Медицинская библиотека · JACC. Cardiovascular interventions · 2021

Doppler Velocity Index Outcomes Following Surgical or Transcatheter Aortic Valve Replacement in the PARTNER Trials.

Hahn Rebecca T, Douglas Pamela S, Jaber Wael A, Leipsic Jonathon, Kapadia Samir, Thourani Vinod H, Makkar Raj, Kodali Susheel, Clavel Marie-Annick, Khalique Omar K, Weissman Neil J, Blanke Philipp, Chen Yanjun, Smith Craig R, Mack Michael J, Leon Martin B, Pibarot Philippe

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to assess the association between Doppler velocity index (DVI) and 2-year outcomes for balloon-expandable SAPIEN 3 transcatheter aortic valve replacement (TAVR) and for surgical aortic valve replacement (SAVR).

BACKGROUND

DVI >0.35 is normal for a prosthetic valve, but recent studies suggest that DVI <0.50 is associated with poor outcomes following TAVR.

METHODS

Patients with severe aortic stenosis enrolled in the PARTNER (Placement of Aortic Transcatheter Valve) 2 (intermediate surgical risk) or PARTNER 3 (low surgical risk) trial undergoing TAVR (n = 1,450) or SAVR (n = 1,303) were included. Patients were divided into 3 DVI groups on the basis of core laboratory-assessed discharge or 30-day echocardiograms: DVILOW (≤0.35), DVIINTERMEDIATE (>0.35 to ≤0.50), and DVIHIGH (>0.50). Two-year outcomes were assessed.

RESULTS

Following TAVR, there were no differences among the 3 DVI groups in composite outcomes of death, stroke, or rehospitalization or in any individual components of 2-year outcomes (P > 0.70 for all). Following SAVR, there was no difference among DVI groups in the composite outcome (P = 0.27), but there was a significant association with rehospitalization (P = 0.02). Restricted cubic-spline analysis for combined outcomes showed an increased risk with post-SAVR DVI ≤0.35 but no relationship post-TAVR. DVI ≤0.35 was associated with increased 2-year composite outcome for SAVR (HR: 1.81; 95% CI: 1.29-2.54; P < 0.001), with no adverse outcomes for TAVR (P = 0.86).

CONCLUSIONS

In intermediate- and low-risk cohorts of the PARTNER trials, DVI ≤0.35 predicted worse 2-year outcomes following SAVR, driven primarily by rehospitalization, with no adverse outcomes associated with DVI following TAVR with the balloon-expandable SAPIEN 3 valve.

Для цитирования: Hahn Rebecca T, Douglas Pamela S, Jaber Wael A, Leipsic Jonathon, Kapadia Samir, Thourani Vinod H, Makkar Raj, Kodali Susheel, Clavel Marie-Annick, Khalique Omar K, Weissman Neil J, Blanke Philipp, Chen Yanjun, Smith Craig R, Mack Michael J, Leon Martin B, Pibarot Philippe. Doppler Velocity Index Outcomes Following Surgical or Transcatheter Aortic Valve Replacement in the PARTNER Trials.. JACC. Cardiovascular interventions. 2021. DOI: 10.1016/j.jcin.2021.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.