Achey Rebecca L, Soni Pranay, Kashkoush Ahmed, Davison Mark, Kondylis Efstathios, Moore Nina, Bain Mark

Аннотация

BACKGROUND: Minimally invasive surgery (MIS) for intracranial pathology minimizes surgical morbidity but can come at the cost of operator ergonomics and technical surgical success. Here, the authors present a case series to report the first use of a novel 15-mm tubular retraction system with integrated lighting and visualization capabilities for MIS access to intracranial lesions.

OBJECTIVE: To demonstrate feasibility and effectiveness of the 15-mm Aurora Surgiscope (Integra Lifesciences) for intracranial MIS approaches.

METHODS: The 15-mm Aurora Surgiscope facilitated MIS approach to gain access to intraparenchymal pathologies. The device consists of a tubular access system with integrated light source and a reusable control unit that modifies video parameters. The port was inserted along a preplanned trajectory through a mini-craniotomy. Bimanual access allowed the surgeon to comfortably dissect/resect lesional tissue using high-quality video.

RESULTS: Four patients are presented. In cases 1 and 2, the authors evacuated acute intracerebral hemorrhages. Both had <15 cc hemorrhage with improved or stable neurological examination. In case 3, the authors performed gross total resection of a cerebellar pilocytic astrocytoma. In case 4, the authors resected a mesial posterior temporal cavernoma. No perioperative/technical complications were noted.

CONCLUSION: The Aurora Surgiscope system is a novel integrated tubular retraction, lighting, and visualization system that allows access to a wide variety of pathologies using a MIS approach. The Surgiscope allows the surgeon to use bimanual dexterity through a small access port while limiting the need for additional equipment such as microscope, exoscope, or endoscope.