MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejim.2024.05.029

Медицинская библиотека · European journal of internal medicine · 2024

Diagnosis of acute aortic syndromes with ultrasound and d-dimer: the PROFUNDUS study.

Morello Fulvio, Bima Paolo, Castelli Matteo, Capretti Elisa, de Matos Soeiro Alexandre, Cipriano Alessandro, Costantino Giorgio, Vanni Simone, Leidel Bernd A, Kaufmann Beat A, Osman Adi, Candelli Marcello, Capsoni Nicolò, Behringer Wilhelm, Capuano Marialessia, Ascione Giovanni, Leal Tatiana de Carvalho Andreucci Torres, Ghiadoni Lorenzo, Pivetta Emanuele, Grifoni Stefano, Lupia Enrico, Nazerian Peiman, PROFUNDUS Study Investigators

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

In patients complaining common symptoms such as chest/abdominal/back pain or syncope, acute aortic syndromes (AAS) are rare underlying causes. AAS diagnosis requires urgent advanced aortic imaging (AAI), mostly computed tomography angiography. However, patient selection for AAI poses conflicting risks of misdiagnosis and overtesting.

OBJECTIVES

We assessed the safety and efficiency of a diagnostic protocol integrating clinical data with point-of-care ultrasound (POCUS) and d-dimer (single/age-adjusted cutoff), to select patients for AAI.

METHODS

This prospective study involved 12 Emergency Departments from 5 countries. POCUS findings were integrated with a guideline-compliant clinical score, to define the integrated pre-test probability (iPTP) of AAS. If iPTP was high, urgent AAI was requested. If iPTP was low and d-dimer was negative, AAS was ruled out. Patients were followed for 30 days, to adjudicate outcomes.

RESULTS

Within 1979 enrolled patients, 176 (9 %) had an AAS. POCUS led to net reclassification improvement of 20 % (24 %/-4 % for events/non-events, P < 0.001) over clinical score alone. Median time to AAS diagnosis was 60 min if POCUS was positive vs 118 if negative (P = 0.042). Within 941 patients satisfying rule-out criteria, the 30-day incidence of AAS was 0 % (95 % CI, 0-0.41 %); without POCUS, 2 AAS were potentially missed. Protocol rule-out efficiency was 48 % (95 % CI, 46-50 %) and AAI was averted in 41 % of patients. Using age-adjusted d-dimer, rule-out efficiency was 54 % (difference 6 %, 95 % CI, 4-9 %, vs standard cutoff).

CONCLUSIONS

The integrated algorithm allowed rapid triage of high-probability patients, while providing safe and efficient rule-out of AAS. Age-adjusted d-dimer maximized efficiency.

CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov, NCT04430400.

Для цитирования: Morello Fulvio, Bima Paolo, Castelli Matteo, Capretti Elisa, de Matos Soeiro Alexandre, Cipriano Alessandro, Costantino Giorgio, Vanni Simone, Leidel Bernd A, Kaufmann Beat A, Osman Adi, Candelli Marcello, Capsoni Nicolò, Behringer Wilhelm, Capuano Marialessia, Ascione Giovanni, Leal Tatiana de Carvalho Andreucci Torres, Ghiadoni Lorenzo, Pivetta Emanuele, Grifoni Stefano, Lupia Enrico, Nazerian Peiman, PROFUNDUS Study Investigators. Diagnosis of acute aortic syndromes with ultrasound and d-dimer: the PROFUNDUS study.. European journal of internal medicine. 2024. DOI: 10.1016/j.ejim.2024.05.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.