Donath Tilman, Pfeiffer Franz, Bunk Oliver, Grünzweig Christian, Hempel Eckhard, Popescu Stefan, Vock Peter, David Christian
Аннотация
OBJECTIVES: X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a conventional x-ray tube source. Feasibility and potential applications of preclinical and clinical phase-contrast CT are discussed.
MATERIALS AND METHODS: A hand of an infant was scanned ex vivo at 40 kVp tube voltage. The simultaneously recorded attenuation and phase-contrast CT images were quantitatively compared with each other, by introducing a specific Hounsfield unit for phase-contrast imaging.
RESULTS: We observe significantly enhanced soft-tissue contrast in the phase images, when compared with the attenuation data. Particularly, tendons and ligaments appear with strongly increased contrast-to-noise ratio.
CONCLUSIONS: Our results demonstrate the huge potential of phase-contrast CT for clinical investigations of human specimens and, potentially, of humans. Because the applied technique works efficiently with conventional x-ray tubes and detectors, it is suitable for the realization of preclinical and clinical phase-contrast CT systems.
MATERIALS AND METHODS: A hand of an infant was scanned ex vivo at 40 kVp tube voltage. The simultaneously recorded attenuation and phase-contrast CT images were quantitatively compared with each other, by introducing a specific Hounsfield unit for phase-contrast imaging.
RESULTS: We observe significantly enhanced soft-tissue contrast in the phase images, when compared with the attenuation data. Particularly, tendons and ligaments appear with strongly increased contrast-to-noise ratio.
CONCLUSIONS: Our results demonstrate the huge potential of phase-contrast CT for clinical investigations of human specimens and, potentially, of humans. Because the applied technique works efficiently with conventional x-ray tubes and detectors, it is suitable for the realization of preclinical and clinical phase-contrast CT systems.