DOI 10.1097/rli.0b013e3181e21866

Медицинская библиотека · Investigative radiology · 2010

Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen.

Donath Tilman, Pfeiffer Franz, Bunk Oliver, Grünzweig Christian, Hempel Eckhard, Popescu Stefan, Vock Peter, David Christian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a conventional x-ray tube source. Feasibility and potential applications of preclinical and clinical phase-contrast CT are discussed.

MATERIALS AND

METHODS

A hand of an infant was scanned ex vivo at 40 kVp tube voltage. The simultaneously recorded attenuation and phase-contrast CT images were quantitatively compared with each other, by introducing a specific Hounsfield unit for phase-contrast imaging.

RESULTS

We observe significantly enhanced soft-tissue contrast in the phase images, when compared with the attenuation data. Particularly, tendons and ligaments appear with strongly increased contrast-to-noise ratio.

CONCLUSIONS

Our results demonstrate the huge potential of phase-contrast CT for clinical investigations of human specimens and, potentially, of humans. Because the applied technique works efficiently with conventional x-ray tubes and detectors, it is suitable for the realization of preclinical and clinical phase-contrast CT systems.

Для цитирования: Donath Tilman, Pfeiffer Franz, Bunk Oliver, Grünzweig Christian, Hempel Eckhard, Popescu Stefan, Vock Peter, David Christian. Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen.. Investigative radiology. 2010. DOI: 10.1097/rli.0b013e3181e21866.

Предметные рубрики MeSH