Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease.

Machann Wolfram, Geier Oliver, Koeppe Sabrina, O'Donnell Thomas, Greiser Andreas, Breunig Frank, Sandstede Joern, Hahn Dietbert, Koestler Herbert, Beer Meinrad

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Late enhancement (LE) imaging is increasingly used for diagnosis of non-ischemic cardiomyopathy. However, the mostly patchy appearance of LE in this context may reduce the reproducibility of LE measurement.

PURPOSE: To report intra- and inter-observer variabilities of LE measurements in Fabry disease using manual and semi-automated quantification.

MATERIAL AND

METHODS

Twenty MRI data-sets of male patients aged 44 ± 7 years were analyzed twice (interval 12 months) by one observer and additionally once by a second observer. Left ventricular (LV) parameters were determined using cine MRI. Gradient-echo LE images were analyzed by manual planimetry and by a semi-automatic prototype software. Variabilities were determined by Bland-Altman analyses and additionally intra-class correlation coefficient (ICC) values were calculated to survey intra- and inter-observer reproducibility.

RESULTS

The amount of LE was 5.2 ± 5.1 mL or 2.8 ± 2.6 % of LV mass (observer 2). LE was detected predominantly intramurally in a patchy pattern. All patients had LE restricted to the basal infero-lateral parts of the LV. The extent of LE correlated to LV mass (207 ± 70 g, P < 0.05, r = 0.6). The intra- and inter-observer variabilities were -0.6 to 1.0 mL and -0.7 to 1.6 mL, respectively (95% confidence intervals). ICC values were 0.981-0.999. The semi-automatic software allowed quantification of LE areas in all patients. The comparison of LE amount determined by semi-automatic software versus manual planimetry yielded an intra-observer variability ranging from -1.9 to 2.3 mL.

CONCLUSION

Semi-automatic planimetry of patchy LE in patients with Fabry disease is feasible. The determined intra- and inter-observer variabilities for manual and semi-automatic planimetry were in the range of 20-40% of LE amount with high ICC values.

Для цитирования: Machann Wolfram, Geier Oliver, Koeppe Sabrina, O'Donnell Thomas, Greiser Andreas, Breunig Frank, Sandstede Joern, Hahn Dietbert, Koestler Herbert, Beer Meinrad. Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease.. Acta radiologica (Stockholm, Sweden : 1987). 2013. DOI: 10.1177/0284185113505275.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.