MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbio.202400058

Медицинская библиотека · Journal of biophotonics · 2024

Multiwavelength laser diode based portable photoacoustic and ultrasound imaging system for point of care applications.

Mitra Mahaan, Haworth Abigail, Gaddale Prameth, Badran Faisal, Lagno Nuzhath, Pameijer Colette, Aziz Faisal, Kothapalli Sri-Rajasekhar

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Vascular diseases are a leading cause of death and disability worldwide. Despite having precursor conditions like peripheral arterial disease (PAD), they are often only diagnosed after the onset of stroke or heart attack. Low-cost, portable, noninvasive, point-of-care (POC), label-free assessment of deep vascular function benefits PAD diagnosis, especially in resource poor settings of the world. Doppler ultrasound-based blood flow measurements can diagnose PAD, albeit with limited sensitivity and specificity. To overcome this, here, we propose the first-of-its-kind dual-modality photoacoustic-and-ultrasound (PAUS) imaging system that integrates a multiwavelength pulsed laser diode (PLD) with a compact ultrasound data acquisition unit. The mesoscopic imaging depth of the portable PLD-PAUS system was validated using tissue phantoms, and its multispectral photoacoustic imaging capabilities were validated using an atherosclerosis-mimicking phantom. Furthermore, we demonstrated high-contrast volumetric in vivo photoacoustic imaging of rodent abdominal vasculature and quantified vessel reactivity due to hypercapnia stimulation. The multiparametric functional and molecular imaging capabilities of the PLD-PAUS system holds promise for POC applications.

Для цитирования: Mitra Mahaan, Haworth Abigail, Gaddale Prameth, Badran Faisal, Lagno Nuzhath, Pameijer Colette, Aziz Faisal, Kothapalli Sri-Rajasekhar. Multiwavelength laser diode based portable photoacoustic and ultrasound imaging system for point of care applications.. Journal of biophotonics. 2024. DOI: 10.1002/jbio.202400058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.