Head & neck · 2013
Surgical outcomes of robotic thyroid surgery using a double incision gasless transaxillary approach: analysis of 400 cases treated by the same surgeon.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lee Yu-Mi, Yi Onvox, Sung Tae-Yon, Chung Ki-Wook, Yoon Jong Ho, Hong Suck Joon
Аннотация
BACKGROUND: The purpose of this study was to evaluate the surgical outcomes of 400 cases of robotic thyroid surgery using a double incision gasless transaxillary approach.
METHODS: We analyzed 400 patients who underwent a robot-assisted thyroidectomy performed by a single surgeon.
RESULTS: All patients underwent successful operations without conversion to open surgery. Transient hypoparathyroidism was the most common complication (51.7%) and permanent hypoparathyroidism occurred in only 2 patients (1.4%). The mean number of retrieved central lymph nodes was 6.5 ± 4.4 for ipsilateral central compartment node dissection and 8.4 ± 5.1 for bilateral central compartment node dissection. The proportion of patients with stimulated thyroglobulin (sTg) levels at the time of remnant ablation <10 ng/mL and sTg levels 6 to 12 months after the first ablation <1 ng/mL was 84.9% and 88.3%, respectively.
CONCLUSION: Robotic thyroid surgery is technically safe and may be a surgical option for patients with well-differentiated thyroid cancer.
METHODS: We analyzed 400 patients who underwent a robot-assisted thyroidectomy performed by a single surgeon.
RESULTS: All patients underwent successful operations without conversion to open surgery. Transient hypoparathyroidism was the most common complication (51.7%) and permanent hypoparathyroidism occurred in only 2 patients (1.4%). The mean number of retrieved central lymph nodes was 6.5 ± 4.4 for ipsilateral central compartment node dissection and 8.4 ± 5.1 for bilateral central compartment node dissection. The proportion of patients with stimulated thyroglobulin (sTg) levels at the time of remnant ablation <10 ng/mL and sTg levels 6 to 12 months after the first ablation <1 ng/mL was 84.9% and 88.3%, respectively.
CONCLUSION: Robotic thyroid surgery is technically safe and may be a surgical option for patients with well-differentiated thyroid cancer.