Annals of vascular surgery · 2021
The Results of The Interposition Graft-Technique in Treatment of High Flow Vascular Access.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Borghese Ottavia, Pisani Angelo, Centa Isabelle Di
Аннотация
OBJECTIVE: High-flow (HF) vascular access (VA) is a fearsome condition potentially responsible for cardiac or pulmonary complications, steal syndrome and hand ischemia. The present study was conducted to report the results achieved in a group of patients undergoing interposition-graft technique to treat HF.
MATERIALS AND METHODS: An analysis of clinical, ultrasound and echocardiography data collected from the review of medical charts was performed. Flow reduction, complications and need for secondary interventions were investigated.
RESULTS: Among a total 498 hemodialysis access interventions performed during a 6-years period, 30 patients (n 15, 50% male, median age 63.5, range 42-91 years) presented with high-flow (median flow 1.9 L/min, range 1.5-4 L/min). 18 patients were asymptomatic (60%); 6 (20%) suffered from a severe distal hand ischemia; 5 (16.6%) developed signs of congestive heart failure and 1 patient (3.3%) presented with pulmonary hypertension. In twenty patients (66.7%) the access was preserved by the interposition of a 6 mm polytetrafluroethylene (PTFE) prosthesis. This approach was used as a primary flow reduction technique in 16 patients (80%) or the failure of a previously attempted procedure in 4 cases. No intraoperative complications were observed. Post-operative median VA flow was 1.1 L/min (range 0.900-2 L/min), with a median flow reduction of 0.770 L/min (range 0.100-2.8 L/min). At a median follow-up of 9 months (range 1-42), 95% (n 19) of patients were free from recurrences.
CONCLUSION: In treatment of HF-VA graft interposition demonstrated satisfactory results at the mid-term follow-up. More data are needed to affirm this technique as the preferential one.
MATERIALS AND METHODS: An analysis of clinical, ultrasound and echocardiography data collected from the review of medical charts was performed. Flow reduction, complications and need for secondary interventions were investigated.
RESULTS: Among a total 498 hemodialysis access interventions performed during a 6-years period, 30 patients (n 15, 50% male, median age 63.5, range 42-91 years) presented with high-flow (median flow 1.9 L/min, range 1.5-4 L/min). 18 patients were asymptomatic (60%); 6 (20%) suffered from a severe distal hand ischemia; 5 (16.6%) developed signs of congestive heart failure and 1 patient (3.3%) presented with pulmonary hypertension. In twenty patients (66.7%) the access was preserved by the interposition of a 6 mm polytetrafluroethylene (PTFE) prosthesis. This approach was used as a primary flow reduction technique in 16 patients (80%) or the failure of a previously attempted procedure in 4 cases. No intraoperative complications were observed. Post-operative median VA flow was 1.1 L/min (range 0.900-2 L/min), with a median flow reduction of 0.770 L/min (range 0.100-2.8 L/min). At a median follow-up of 9 months (range 1-42), 95% (n 19) of patients were free from recurrences.
CONCLUSION: In treatment of HF-VA graft interposition demonstrated satisfactory results at the mid-term follow-up. More data are needed to affirm this technique as the preferential one.
Предметные рубрики MeSH
AdultAgedAged, 80 and overArteriovenous Shunt, SurgicalBlood Flow VelocityBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationFemaleFranceHumansMaleMiddle AgedPolytetrafluoroethylenePostoperative ComplicationsProsthesis DesignRenal DialysisRetrospective StudiesRisk FactorsTime FactorsTreatment OutcomeVascular Patency