MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2013.01.067

Медицинская библиотека · Biosensors & bioelectronics · 2013

Development of a label-free immunosensor based on surface plasmon resonance technique for the detection of anti-Leishmania infantum antibodies in canine serum.

Souto Dênio E P, Silva Jussara V, Martins Helen R, Reis Alexandre B, Luz Rita C S, Kubota Lauro T, Damos Flávio S

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In this work, a surface plasmon resonance (SPR) immunosensor was developed using an 11-mercaptoundecanoic acid (11-MUA) modified gold SPR sensor chip for the detection of anti-Leishmania infantum antibodies. The soluble antigens of L. infantum were securely immobilized on an SPR gold disk by an 11-MUA self-assembled monolayer. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electrochemical microscopy (SECM) techniques were employed in the characterization of the antigen immobilization. After the immunosensor construction, canine serum positive for visceral leishmaniasis was added to its surface and showed significant variation in the SPR angle, indicating excellent sensitivity of the technique for antigen-antibody interaction detection. Moreover, the addition of negative serum was accompanied by a smaller response, demonstrating that the immunosensor shows good specificity against anti-L. infantum antibodies. Therefore, this work demonstrates the successful development of an SPR sensor for anti-L. infantum antibodies detection in short time, showing a great perspective as a sensing system of visceral leishmaniasis in endemic regions.

Для цитирования: Souto Dênio E P, Silva Jussara V, Martins Helen R, Reis Alexandre B, Luz Rita C S, Kubota Lauro T, Damos Flávio S. Development of a label-free immunosensor based on surface plasmon resonance technique for the detection of anti-Leishmania infantum antibodies in canine serum.. Biosensors & bioelectronics. 2013. DOI: 10.1016/j.bios.2013.01.067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.