m+Medelevator.RU
← Поиск публикаций
Journal of thrombosis and haemostasis : JTH · 2019

Diagnostic utility of the ISTH bleeding assessment tool in patients with suspected platelet function disorders.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Adler Marcel, Kaufmann Jonas, Alberio Lorenzo, Nagler Michael

Аннотация

UNLABELLED: Essentials The utility of bleeding assessment tools regarding platelet function disorders is still elusive. We studied consecutive patients in a prospective cohort study in a tertiary hospital. Substantially higher scorings were observed in patients with platelet function disorders. Bleeding assessment tools might provide a useful screening tool.

BACKGROUND: Bleeding assessment tools (BATs) have been widely implemented in the evaluation of patients with suspected bleeding disorders. However, diagnostic BAT utility regarding platelet function disorders is still elusive.

AIM: We aimed to assess the diagnostic value of the International Society on Thrombosis and Haemostasis BAT (ISTH-BAT) for platelet function disorders in clinical practice.

METHODS: The clinical characteristics and laboratory data of all consecutive patients with a suspected bleeding disorder referred between January 2012 and March 2017 to an outpatient unit of a university hospital were prospectively collected. The diagnostic evaluation was performed according to current recommendations following a prespecified protocol and platelet function was tested using light transmission aggregometry as well as flow cytometry.

RESULTS: Five hundred and fifty-five patients were assessed; 66.9% were female, median age was 43.7 years (interquartile range [IQR] 29.3, 61.7). Confirmed platelet function disorder was diagnosed in 54 patients (9.7%), possible platelet function disorder in 64 patients (11.5%), and other disorders in 170 patients (30.6%). Median scoring of the ISTH-BAT was 2 in patients without a bleeding disorder (IQR 1, 3), 4 in patients with a possible platelet function disorder (2, 7), and 7 in patients with confirmed platelet function disorder (5, 9). Area under the receiver operating characteristic curve (the area under the curve [AUC]) was 0.75 (95% CI 0.70, 0.80).

CONCLUSIONS: Presence of a platelet function disorder was associated with substantially higher BAT scorings compared to patients without. Our data suggest that the ISTH-BAT provides a useful screening tool for patients with suspected platelet function disorders.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты