DOI 10.1016/j.jvscit.2017.12.004
Recovery of lost motor evoked potentials in open thoracoabdominal aortic aneurysm repair using intercostal artery bypass.
Аннотация
Ischemia of the spinal cord remains a disastrous complication in thoracoabdominal aortic aneurysm (TAAA) surgery. We report a case of open type I TAAA repair during which no motor evoked potentials were detectable for >1 hour after aortic cross-clamping. The creation of three intercostal artery bypasses restored spinal cord perfusion. As the patient showed only moderate clinical signs of spinal cord ischemia afterward, we underline the role of neuromonitoring to guide intercostal artery bypass implantation during TAAA surgery as the combined use of neuromonitoring and intercostal artery bypass implantation may prevent paraplegia in specific TAAA cases.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.