m+Medelevator.RU
← Поиск публикаций
Hepatology research : the official journal of the Japan Society of Hepatology · 2023

Diagnostic accuracy of enhanced liver fibrosis test for nonalcoholic steatohepatitis-related fibrosis: Multicenter study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Seko Yuya, Takahashi Hirokazu, Toyoda Hidenori, Hayashi Hideki, Yamaguchi Kanji, Iwaki Michihiro, Yoneda Masato, Arai Taeang, Shima Toshihide, Fujii Hideki, Morishita Asahiro, Kawata Kazuhito, Tomita Kengo, Kawanaka Miwa, Yoshida Yuichi, Ikegami Tadashi, Notsumata Kazuo, Oeda Satoshi, Kamada Yoshihiro, Sumida Yoshio, Fukushima Hideaki, Miyoshi Eiji, Aishima Shinichi, Okanoue Takeshi, Nakajima Atsushi, Itoh Yoshito, Japan Study Group of Nonalcoholic Fatty Liver Disease (JSG-NAFLD)

Аннотация

AIM: The enhanced liver fibrosis (ELF) test is a noninvasive method for diagnosing hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). This multicenter cohort study aimed to evaluate the accuracy of the ELF test and compare it with other noninvasive tests in Japan.

METHODS: We analyzed 371 Japanese patients with biopsy-proven NAFLD. We constructed area under the receiver operator characteristic curves (AUROC) to determine the diagnostic accuracies of the ELF test, the Mac-2-binding protein glycosylation isomer (M2BPGi), the Fibrosis-4 (FIB-4) index, and combinations of these indices.

RESULTS: In patients with F0/F1/F2/F3/F4 fibrosis, the median values of the ELF test were 8.98/9.56/10.39/10.92/11.41, respectively. The AUROCs of the ELF test for patients with F0 versus F1-4, F0-1 versus F2-4, F0-2 versus F3-4, and F0-3 versus F4 fibrosis were 0.825/0.817/0.802/0.812, respectively. The AUROCs of the ELF test were greater than those of the FIB-4 index and M2BPGi at each fibrosis stage. Respective low and high cut-off values yielded sensitivities and specificities for predicting advanced fibrosis (≥F3) of 91.1% and 50.8%, and 38.5% and 92.8%, respectively. For F3 or F4 fibrosis, the combined values from the ELF test and FIB-4 index showed a sensitivity of 98.5%, and the combined values from the ELF test and M2BPGi assay showed a specificity of 97.5%.

CONCLUSIONS: In Japan, the ELF test predicts NAFLD-related fibrosis from its early stages. The diagnostic ability of the ELF test was not inferior to that of other indices, and the combined values of ELF plus other indices were more accurate.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты