Degradation and interaction with bone of magnesium alloy WE43 implants: A long-term follow-up in vivo rat tibia study.

Oshibe Narumi, Marukawa Eriko, Yoda Tetsuya, Harada Hiroyuki

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The aim of this in vivo study was to examine the degradation and biocompatibility of the WE43 magnesium alloy containing magnesium yttrium, rare earth elements, and zirconium over a one-year long-term follow-up period. Additionally, we compared anodized WE43 implants with monolithic ones and clarified the effect of the anodization. WE43 cylindrical implants with and without anodization (length, 10 mm; diameter, 0.3 mm) were transplanted into the rat tibia. In both groups, the development of corrosion and the change in implant volume were evaluated by in vivo micro-computed tomography until 12 months, and the bone tissue reaction was observed histologically. In the monolithic WE43 implants, hydrogen gas was evident until 14 days and the volume loss was 36.3% after 12 months. In the anodized WE43 implants, the development of hydrogen gas was inhibited and the volume loss was 27.7% after 12 months. The anodized WE43 implants showed a significantly slower corrosion process in the early phase. Therefore, these implants may require a prolonged period to degrade completely and may even resist complete degradation. At one year post surgery, bone maturation progressed and lamellar bone structure developed around the implant in both groups. In conclusion, the WE43 implants showed good long-term stability and biocompatibility in bone tissue.

Для цитирования: Oshibe Narumi, Marukawa Eriko, Yoda Tetsuya, Harada Hiroyuki. Degradation and interaction with bone of magnesium alloy WE43 implants: A long-term follow-up in vivo rat tibia study.. Journal of biomaterials applications. 2019. DOI: 10.1177/0885328218822050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.