Evaluation of non-Gaussian diffusion in cardiac MRI.

McClymont Darryl, Teh Irvin, Carruth Eric, Omens Jeffrey, McCulloch Andrew, Whittington Hannah J, Kohl Peter, Grau Vicente, Schneider Jürgen E

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: The diffusion tensor model assumes Gaussian diffusion and is widely applied in cardiac diffusion MRI. However, diffusion in biological tissue deviates from a Gaussian profile as a result of hindrance and restriction from cell and tissue microstructure, and may be quantified better by non-Gaussian modeling. The aim of this study was to investigate non-Gaussian diffusion in healthy and hypertrophic hearts.

METHODS

Thirteen rat hearts (five healthy, four sham, four hypertrophic) were imaged ex vivo. Diffusion-weighted images were acquired at b-values up to 10,000 s/mm2 . Models of diffusion were fit to the data and ranked based on the Akaike information criterion.

RESULTS

The diffusion tensor was ranked best at b-values up to 2000 s/mm2 but reflected the signal poorly in the high b-value regime, in which the best model was a non-Gaussian "beta distribution" model. Although there was considerable overlap in apparent diffusivities between the healthy, sham, and hypertrophic hearts, diffusion kurtosis and skewness in the hypertrophic hearts were more than 20% higher in the sheetlet and sheetlet-normal directions.

CONCLUSION

Non-Gaussian diffusion models have a higher sensitivity for the detection of hypertrophy compared with the Gaussian model. In particular, diffusion kurtosis may serve as a useful biomarker for characterization of disease and remodeling in the heart. Magn Reson Med 78:1174-1186, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

Для цитирования: McClymont Darryl, Teh Irvin, Carruth Eric, Omens Jeffrey, McCulloch Andrew, Whittington Hannah J, Kohl Peter, Grau Vicente, Schneider Jürgen E. Evaluation of non-Gaussian diffusion in cardiac MRI.. Magnetic resonance in medicine. 2016. DOI: 10.1002/mrm.26466.