MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005373-200210000-00019

Медицинская библиотека · The Journal of trauma · 2002

Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation.

Chen Andrew L, Joseph Thomas N, Wolinksy Phillip R, Tejwani Nirmal C, Kummer Frederick J, Egol Kenneth A, Koval Kenneth J

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This study compared the fixation stability of two treatments for humeral shaft fractures with segmental bone loss during cyclic, physiologic loading.

METHODS

Six matched pairs of human humeri received either a 10-hole broad dynamic compression plate or a locked antegrade inserted humeral nail applied to a humeral diaphyseal osteotomy with a 1.5-cm gap defect. The bone-implant humeral constructs were axially loaded for 10,000 cycles at 250 N and 500 N, with measurements of gap displacement and calculation of construct stiffness. The specimens were then loaded to failure.

RESULTS

Cyclic loading showed no difference between the two groups for average gap displacement or construct stiffness. The intramedullary nail constructs failed by humeral shaft splitting (n = 4) or head cut-out (n = 2) at an average of 958.3 N, whereas the plate constructs failed by humeral shaft splitting and screw pull-out (n = 3) or plate bending (n = 3) at an average of 641.7 N (p < 0.001).

CONCLUSION

Although both methods offer similar fixation stability under physiologic loads, the higher load to failure demonstrated by intramedullary nail fixation may have implications for the patient with multiple injuries for whom partial weightbearing on the injured upper extremity may be necessary.

Для цитирования: Chen Andrew L, Joseph Thomas N, Wolinksy Phillip R, Tejwani Nirmal C, Kummer Frederick J, Egol Kenneth A, Koval Kenneth J. Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation.. The Journal of trauma. 2002. DOI: 10.1097/00005373-200210000-00019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.