MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bbrc.2007.12.075

Медицинская библиотека · Biochemical and biophysical research communications · 2007

Serum proteomic-based analysis for the identification of a potential serological marker for autoimmune hepatitis.

Lu Feng, Xia Qing, Ma Yuanfang, Yuan Guogang, Yan Huiping, Qian Lu, Hu Meiru, Wang Mingli, Lu Han, Wang Hongli, Liu Bingyu, Xue Yan, Wang Hongxia, Li Mingyuan, Shen Beifen, Guo Ning

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In the present study, by using a serologic proteomic analysis, we identified phosphoglycerate mutase isozyme B (PGAM-B) as a putative target of autoantibodies in autoimmune hepatitis (AIH). To evaluate whether the identified autoantigen is crucial for AIH, we cloned PGAM-B cDNA and expressed the recombinant protein in Escherichia coli. The soluble PGAM-B was purified by affinity chromatography and used as a coating antigen to determine the frequency of the PGAM-B-autoantibodies (PGAM-B-Abs) in patients with AIH and primary biliary cirrhosis (PBC) as well as chronic hepatitis B (CHB), chronic hepatitis C (CHC), and healthy donors by ELISA. Our study showed that the autoantibody to PGAM-B was predominantly present in AIH patients and 70.04% (50/71) of the tested AIH sera reacted to PGAM-B. The frequency of autoantibodies to PGAM-B is much higher in patients with AIH than in patients with PBC, CHB, CHC, and normal control. The data were further confirmed by using 1-DE Western blot analysis. Our study presents the first description of this protein as a candidate of diagnostic marker for AIH.

Для цитирования: Lu Feng, Xia Qing, Ma Yuanfang, Yuan Guogang, Yan Huiping, Qian Lu, Hu Meiru, Wang Mingli, Lu Han, Wang Hongli, Liu Bingyu, Xue Yan, Wang Hongxia, Li Mingyuan, Shen Beifen, Guo Ning. Serum proteomic-based analysis for the identification of a potential serological marker for autoimmune hepatitis.. Biochemical and biophysical research communications. 2007. DOI: 10.1016/j.bbrc.2007.12.075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.