Appropriate use of wearable defibrillators with multiparametric evaluation to avoid unnecessary defibrillator implantation.

Matteucci Andrea, Pignalberi Carlo, Di Fusco Stefania, Aiello Alessandro, Aquilani Stefano, Nardi Federico, Colivicchi Furio

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Wearable cardioverter-defibrillators (WCD) have emerged as a valuable tool in the management of patients at risk for life-threatening arrhythmias. These devices offer a non-invasive and temporary solution, providing continuous monitoring and the potential for prompt defibrillation when needed. In this study, we explore the use of WCD and evaluate arrhythmic events through comprehensive monitoring.

METHODS

From November 2022 to May 2024, we conducted an outpatient follow-up of 41 patients receiving WCD. Regular check-ups, remote monitoring and comprehensive echocardiography were performed to optimise a tailored therapy.

RESULTS

The average age of the patients was 59.2.4±16.5 years, with 78% being male. Among the cohort, 54% had hypertension, 41% were smokers and 66% had dyslipidaemia, while 27% were diabetic. WCD was assigned according to the Italian Association of Hospital Cardiologists position paper focussing on the appropriate use of WCD and European Society of Cardiology guidelines on ventricular arrhythmias and the prevention of sudden cardiac death: 24 (58%) patients had a de novo diagnosis of heart failure with reduced ejection fraction, 11 (27%) patients had a recent acute coronary syndrome and ejection fraction <35%, 3 (7%) patients had a cardiac electronic device extraction and 3 (7%) patients had myocarditis with features of electrical instability. The average follow-up was 62±38 days according to specific aetiology, with a daily wearing time of 22.7±1.3 hours. No device interventions were recorded. At the end of the follow-up period, 15 patients still required an implantable cardioverter-defibrillator (ICD). Among these, 12 patients (29%) underwent ICD implantation. Two patients (5%) declined the procedure.

CONCLUSIONS

The use of WCD for patients at high risk of arrhythmias allowed to optimise therapy and limit the indications for ICD. Inappropriate implantation of ICD was avoided in 69% of patients who received WCD. The device showed a good safety profile, low incidence of device interventions and adequate patients' adherence to WCD use.

Для цитирования: Matteucci Andrea, Pignalberi Carlo, Di Fusco Stefania, Aiello Alessandro, Aquilani Stefano, Nardi Federico, Colivicchi Furio. Appropriate use of wearable defibrillators with multiparametric evaluation to avoid unnecessary defibrillator implantation.. Open heart. 2024. DOI: 10.1136/openhrt-2024-002787.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.