OBJECTIVES

Hydroxyapatite is a commonly used material for medical applications due to its excellent biocompatibility. We use hydroxyapatite prosthesis for the reconstruction of the ossicular chain in stapes surgery. In this study, we report a case series of endoscopic ear surgery using a basket-type hydroxyapatite prosthesis.

METHODS

We retrospectively examined 8 cases of endoscopic transcanal stapes surgery using hydroxyapatite prostheses. We evaluated the postoperative results and complications.

RESULTS

The average postoperative air-bone gaps were within 10 dB in all cases. Postoperative sensorineural hearing loss was not observed in any case. There was an intraoperative complication with the chorda tympani in 1 patient. We were able to preserve the chorda tympani of all patients, including this case. Postoperative transient dizziness and transient taste disorder were observed in 50% of cases. No other complications, including facial nerve palsy, tympanic membrane perforation, or postoperative infection, were observed.

CONCLUSIONS

The postoperative results and complications were comparable to those of surgery under a microscope. The hydroxyapatite prosthesis could be a possible alternative for the piston-type titanium or polytetrafluoroethylene prosthesis.

Для цитирования: Hosoya Makoto, Fujioka Masato, Ogawa Kaoru. Hydroxyapatite Prostheses in Endoscopic Transcanal Stapes Surgery for Otosclerosis Cases.. Ear, nose, & throat journal. 2021. DOI: 10.1177/0145561321989143.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.