MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2018.03.043

Медицинская библиотека · American journal of ophthalmology · 2018

The Safety and Efficacy of Supraciliary Stenting Following Failed Glaucoma Surgery.

Kerr Nathan M, Wang Jing, Perucho Lucia, Barton Keith

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and efficacy of supraciliary stenting following failed glaucoma surgery.

DESIGN

Interventional case series.

METHODS

Setting

Moorfields Eye Hospital, London, United Kingdom.

STUDY POPULATION: Twenty eyes from 20 patients with glaucoma refractory to prior glaucoma surgery.

INTERVENTION: Ab interno microstent (CyPass Micro-Stent; Alcon, Fort Worth, Texas, USA) implantation into the supraciliary space.

MAIN OUTCOME MEASURES: Outcome measures included the occurrence of ocular adverse events, mean intraocular pressure (IOP) change, and glaucoma medication use through 12 months.

RESULTS

Mean baseline IOP was 22.5 ± 8.0 mm Hg and number of medications was 2.7 ± 1.0. The majority of patients had undergone either prior trabeculectomy or aqueous shunt surgery. There were no serious intraoperative complications or major adverse events following supraciliary stenting. The most common adverse events included transient hyphema (3/20, 15%), transient IOP > 30 mm Hg (4/20, 20%), and transient IOP < 6 mm Hg (4/20, 20%). At 12 months, mean IOP was 14.9 ± 4.3 mm Hg-a 33.7% reduction (P = .01). Mean medication usage decreased 56% to 1.2 ± 1.5 at 12 months (P = .01). Two patients (10%) required subsequent aqueous shunt insertion.

CONCLUSION

Ab interno supraciliary stenting has a favorable safety profile and provides an effective approach to controlling IOP and reducing medication burden in eyes in which previous glaucoma surgery has failed.

Для цитирования: Kerr Nathan M, Wang Jing, Perucho Lucia, Barton Keith. The Safety and Efficacy of Supraciliary Stenting Following Failed Glaucoma Surgery.. American journal of ophthalmology. 2018. DOI: 10.1016/j.ajo.2018.03.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.