Comparison of one-year outcomes and quality of life between endovenous microwave ablation and high ligation and stripping of the great saphenous vein.
Аннотация
INTRODUCTION
The objective of this study is to evaluate and compare the effectiveness of endovenous microwave ablation (EMA) and high ligation and strippingn (HLS) of the great saphenous vein (GSV) in the treatment of varicose veins.
METHODS
We included 182 patients in each EMA and HLS groups. Follow-up outcomes included AVVQ, VCSS, chronic venous insufficiency questionnaire-14 (CIVIQ14) score, clinical recurrence rate of varicose vein treatment, and patient satisfaction during the 1-year follow-up period.
RESULTS
At the 1-year follow-up, no significant difference was found in the clinical recurrence rate of varicose veins between the EMA and HLS groups (p = .75). The duration of the operation and the length of hospital stay for patients in the EMA group was shorter than that for the HLS group (p < .01). The Aberdeen Varicose Vein Questionnaire (AVVQ), Venous Clinical Severity Score (VCSS) score, and ecchymosis were lower for patients who underwent EMA surgery (p < .01).
CONCLUSION
Our research results confirm that EMA improves patients' quality of life with lower limb varicose veins, with EMA showing higher patient satisfaction.