BACKGROUND

Microneedling is an increasingly popular cosmetic procedure. However, because needles are made of metal, there is concern among aesthetic physicians and nonphysician providers regarding whether these needles pose a risk to individuals with known metal allergies.

OBJECTIVE

To assess nickel release and structural degradation in commonly used microneedling devices.

MATERIALS AND

METHODS

Five brands of used microneedles were tested for nickel release using the dimethylglyoxime (DMG) spot test. Scanning electron microscopy was used to evaluate structural integrity, focusing on cracks and fissures after use.

RESULTS

Of the 5 brands tested, 3 released nickel (Device A, Device B, Device E), while 2 did not (Device C, Device D). Needles from all 5 brands demonstrated cracks and fissures after their use. The presence of structural damage to the needles did not correlate with positive DMG testing. Unexpectedly, at least 4 of the companies (Device A, Device B, Device C, Device E) coat their needles with gold.

CONCLUSION

Nickel and possibly gold ion release from microneedling could elicit allergic contact dermatitis in sensitized individuals. A prospective study of dermatitis and healing times after microneedling in patients with nickel or gold allergies compared with those without such metal allergies is warranted.

Для цитирования: Rigali Sarah, Zeng Cindy, Scheman Andrew, Moraga Richard, Liszewski Walter. Nickel Secretion and the Allergenic Potential of Cosmetic Microneedles.. Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.]. 2025. DOI: 10.1097/dss.0000000000004910.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.