MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/13645706.2013.827121

Медицинская библиотека · Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy · 2013

Percutaneous closure of catheter enterotomy: feasibility determination in vivo.

Roy Sumit, Hol Per Kristian

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: To determine whether a catheter enterotomy can be percutaneously sealed with a commercially available vascular closure implant.

MATERIAL AND

METHODS

The study was performed using a porcine model of small intestinal obstruction. Preliminary experiments were performed to allow an informed choice between two of the most promising commercially available alternatives: A multipronged metal clip (StarClose®) and a resorbable anchored polymer plate (FemoSeal®). Thereafter closure of seven enterotomies was attempted with the most suitable implant. The deployment procedure was subjectively analyzed. The sealed enterotomies were visually evaluated and hydrostatically tested.

RESULTS

StarClose was rejected for formal assessment because it was both difficult to deploy and could not ensure a watertight seal. The conventional method for deploying FemoSeal was found to be inappropriate for percutaneously closing enterotomies. However an improvised accessory allowed all seven enterotomies to be successfully sealed with the implant using a modified procedure that involved only one additional step. After closure, six of the seven enterotomies tolerated intraluminal pressure up to 65 mm Hg.

CONCLUSION

FemoSeal has the potential to serve as an implant for percutaneous closure of catheter enterotomies if the deployment tool can be appropriately modified.

Для цитирования: Roy Sumit, Hol Per Kristian. Percutaneous closure of catheter enterotomy: feasibility determination in vivo.. Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy. 2013. DOI: 10.3109/13645706.2013.827121.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.