Prompt correction of endotracheal tube positioning after intubation prevents further inappropriate positions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rigini Nugzar, Boaz Mona, Ezri Tiberiu, Evron Shmuel, Trigub Dimitry, Jackobashvilli Simon, Izakson Alexander

Аннотация

STUDY OBJECTIVE: To determine whether the timely correction of endotracheal tube (ETT) positioning prevents further inappropriate positions.

DESIGN: Prospective crossover study.

SETTING: University-affiliated hospital.

PATIENTS: 44 adult, ASA physical status 1, 2, and 3 patients undergoing open or laparoscopic abdominal procedures.

INTERVENTIONS: ETT positioning was verified by both auscultation and fiberoptic bronchoscopy (FOB), after intubation, and before extubation. In laparoscopic procedures, two additional measurements were performed: after maximal abdominal gas insufflation and with head-down position. An ETT in the bronchus or at the carina was considered an inappropriate placement. An ETT ≤ one cm from the carina was considered a critical placement.

MEASUREMENTS: The frequency of inappropriate and critical ETT positioning with both auscultation and FOB and the number of ETTs that remained in an incorrect position despite repositioning.

MAIN RESULTS: FOB detected 5 inappropriately positioned ETTs, 4 of which were also detected by chest auscultation (P = 0.99). Critical positioning was detected by FOB in 6 patients, three of which were also detected by auscultation (P = 0.24). There were 15 other "out-of-desired range" positions (out of the 3-5 cm range) - one placed too high and 14 placed too low, while 18 were placed within the range of positions. All patients with inappropriate ETT positioning were women (P = 0.005). Age, body mass index, Mallampati grade > 3, thyromental distance < 6 cm, or laryngoscopy grade ≥ 2 were not associated with either inappropriate or critical placement. No episodes of inappropriate or critical positioning were detected by FOB or auscultation at the end of surgery.

CONCLUSIONS: Early detection and prompt correction of inappropriate ETT positioning after intubation prevented further ETT migration into undesired positions.