Optimal cannula positioning of HeartMate 3 left ventricular assist device.

Imamura Teruhiko, Narang Nikhil, Nitta Daisuke, Fujino Takeo, Nguyen Ann, Kim Gene, Raikhelkar Jayant, Rodgers Daniel, Ota Takeyoshi, Jeevanandam Valluvan, Sayer Gabriel, Uriel Nir

СтатьяПеревод пока не подготовлен

Аннотация

Cannula position in HeartMate II and HeartWare left ventricular assist devices (LVADs) is associated with clinical outcome. This study aimed to investigate the clinical implication of the device positioning in HeartMate 3 LVAD cohort. Consecutive patients who underwent HeartMate 3 LVAD implantation were followed for one year from index discharge. At index discharge, chest X-ray parameters were measured: (a) cannula coronal angle, (b) height of pump bottom, (c) cannula sagittal angle, and (d) cannula lumen area. The association of each measurement of cannula position with one-year clinical outcomes was investigated. Sixty-four HeartMate 3 LVAD patients (58 years old, 64% male) were enrolled. In the multivariable Cox regression model, the cannula coronal angle was a significant predictor of death or heart failure readmission (hazard ratio 1.27 [1.01-1.60], P = .045). Patients with a cannula coronal angle ≤28° had lower central venous pressure (P = .030), lower pulmonary capillary wedge pressure (P = .027), and smaller left ventricular size (P = .019) compared to those with the angle >28°. Right ventricular size and parameters of right ventricular function were also better in the narrow angle group, as was one-year cumulative incidence of death or heart failure readmission (10% vs. 50%, P = .008). Narrow cannula coronal angle in patients with HeartMate 3 LVADs was associated with improved cardiac unloading and lower incidence of death or heart failure readmission. Larger studies to confirm the implication of optimal device positioning are warranted.

Для цитирования: Imamura Teruhiko, Narang Nikhil, Nitta Daisuke, Fujino Takeo, Nguyen Ann, Kim Gene, Raikhelkar Jayant, Rodgers Daniel, Ota Takeyoshi, Jeevanandam Valluvan, Sayer Gabriel, Uriel Nir. Optimal cannula positioning of HeartMate 3 left ventricular assist device.. Artificial organs. 2020. DOI: 10.1111/aor.13755.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.