m+Medelevator.RU
← Поиск публикаций
Ultraschall in der Medizin (Stuttgart, Germany : 1980) · 2011

Endocavitary contrast enhanced ultrasound (CEUS)--work in progress.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Heinzmann A, Müller T, Leitlein J, Braun B, Kubicka S, Blank W

Аннотация

PURPOSE: To demonstrate the benefit concerning localisation, measurement and visualisation of complications of drained fluid collections in the abdomen by applying ultrasound contrast agent via drainage catheters. In addition, to investigate the usefulness of CEUS in applying the agents in the biliary tract or when given orally.

MATERIALS AND METHODS: A single drop of SonoVue® was added to 0.9 % saline solution and instilled via drainage catheters. Location, dimensions and complications of drained fluid collections were recorded and compared to the results of sonographic examination using saline solution alone and fluoroscopic examination using iodinated contrast agents. The biliary system was visualised by applying the solution via nasobiliary drains or via ERC catheterisation. Orally administered solutions consisted of one drop of SonoVue® in 50 ml aqua.

RESULTS: Admixture of an ultrasound contrast agent to saline solution facilitates position monitoring of the drains in fluid collections and provides reliable information on the dimensions of the drained collection. Complications like fistulae to the biliary system, blood vessels, small or large intestine or to the peritoneal cavity are precisely displayed. The biliary system is shown in detailed description. Orally administered, the contrast agent is visible after intake long unto the colon. Insufficient anastomoses or spontaneous perforations become detectable.

CONCLUSION: The application of ultrasound contrast agents via drainage catheters provides substantial information on location and dimensions of drained fluid collections and their communication with surrounding organ structures. The biliary system can be visualised. Oral administration is feasible and provides important additional information.