MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2019/9769724

Медицинская библиотека · Cardiovascular therapeutics · 2019

Outcomes of Cardiac Contractility Modulation: A Systematic Review and Meta-Analysis of Randomized Clinical Trials.

Mando Ramy, Goel Akshay, Habash Fuad, Saad Marwan, Ayoub Karam, Vallurupalli Srikanth, Maskoun Waddah

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac contractility modulation (CCM) is a device therapy for systolic heart failure (HF) in patients with narrow QRS. We aimed to perform an updated meta-analysis of the randomized clinical trials (RCTs) to assess the efficacy and safety of CCM therapy.

METHODS

We conducted a systematic review and meta-analysis of randomized clinical trials (RCTs) between January 2001 and June 2018. Outcomes of interest were peak oxygen consumption (peak VO2), 6-Minute Walk Distance (6MWD), Minnesota Living with Heart Failure Questionnaire (MLHFQ), HF hospitalizations, cardiac arrhythmias, pacemaker/ICD malfunctioning, all-cause hospitalizations, and mortality. Data were expressed as standardized mean difference (SMD) or odds ratio (OR).

RESULTS

Four RCTs including 801 patients (CCM n = 394) were available for analysis. The mean age was 59.63 ± 0.84 years, mean ejection fraction was 29.14 ± 1.22%, and mean QRS duration was 106.23 ± 1.65 msec. Mean follow-up duration was six months. CCM was associated with improved MLWHFQ (SMD -0.69, p = 0.0008). There were no differences in HF hospitalizations (OR 0.76, p = 0.12), 6MWD (SMD 0.67, p = 0.10), arrhythmias (OR 1.40, p = 0.14), pacemaker/ICD malfunction/sensing defect (OR 2.23, p = 0.06), all-cause hospitalizations (OR 0.73, p = 0.33), or all-cause mortality (OR 1.04, p = 0.92) between the CCM and non-CCM groups.

CONCLUSIONS

Short-term treatment with CCM may improve MLFHQ without significant difference in 6MWD, arrhythmic events, HF hospitalizations, all-cause hospitalizations, and all-cause mortality. There is a trend towards increased pacemaker/ICD device malfunction. Larger RCTs might be needed to determine if the CCM therapy will be beneficial with longer follow-up.

Для цитирования: Mando Ramy, Goel Akshay, Habash Fuad, Saad Marwan, Ayoub Karam, Vallurupalli Srikanth, Maskoun Waddah. Outcomes of Cardiac Contractility Modulation: A Systematic Review and Meta-Analysis of Randomized Clinical Trials.. Cardiovascular therapeutics. 2019. DOI: 10.1155/2019/9769724.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.