MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2019/8947204

Медицинская библиотека · Journal of interventional cardiology · 2019

One-Year Mortality in Patients Undergoing Transcatheter Aortic Valve Replacement for Stenotic Bicuspid versus Tricuspid Aortic Valves: A Meta-Analysis and Meta-Regression.

Quintana Raymundo A, Monlezun Dominique J, DaSilva-DeAbreu Adrian, Sandhu Uday G, Okwan-Duodu Derick, Ramírez Jonanlis, Denktas Ali E, Jneid Hani, Paniagua David

СтатьяМетаанализПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess 1-year mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic stenosis (AS).

BACKGROUND

Clinical trials have proven the beneficial effect of TAVR on mortality in patients with tricuspid AS. Individuals with bicuspid AS were excluded from these trials.

METHODS

A meta-analysis using literature search from the Cochrane, PubMed, ClinicalTrials, SCOPUS, and EMBASE databases was conducted to determine the effect of TAVR on 1-year mortality in patients with bicuspid AS. Short-term outcomes that could potentially impact one-year mortality were analyzed.

RESULTS

After evaluating 380 potential articles, 5 observational studies were selected. A total of 3890 patients treated with TAVR were included: 721 had bicuspid and 3,169 had tricuspid AS. No statistically significant difference between the baseline characteristics of the two groups of patients was seen outside of mean aortic gradient. Our primary endpoint of one-year all-cause mortality revealed 85 deaths in 719 patients (11.82%) with bicuspid AS compared to 467 deaths in 3100 patients (15.06%) with tricuspid AS, with no difference between both groups [relative risk (RR) 1.03; 95% CI 0.70-1.51]. Patients with bicuspid AS were associated with a decrease in device success (RR 0.62; 95% CI 0.45-0.84) and an increase in moderate-to-severe prosthetic valve regurgitation (RR 1.55; 95% CI 1.07-2.22) after TAVR compared to patients with tricuspid AS. The effect of meta-regression coefficients on one-year all-cause mortality was not statistically significant for any patient baseline characteristics.

CONCLUSION

When comparing TAVR procedure in tricuspid AS versus bicuspid AS, there was no difference noted in one-year all-cause mortality.

Для цитирования: Quintana Raymundo A, Monlezun Dominique J, DaSilva-DeAbreu Adrian, Sandhu Uday G, Okwan-Duodu Derick, Ramírez Jonanlis, Denktas Ali E, Jneid Hani, Paniagua David. One-Year Mortality in Patients Undergoing Transcatheter Aortic Valve Replacement for Stenotic Bicuspid versus Tricuspid Aortic Valves: A Meta-Analysis and Meta-Regression.. Journal of interventional cardiology. 2019. DOI: 10.1155/2019/8947204.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.