MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00701-023-05778-1

Медицинская библиотека · Acta neurochirurgica · 2023

Reliability of intraoperative visual evoked potentials (iVEPs) in monitoring visual function during endoscopic transsphenoidal surgery.

Mattogno Pier Paolo, D'Alessandris Quintino Giorgio, Rigante Mario, Granata Giuseppe, Di Domenico Michele, Perotti Valerio, Montano Nicola, Giordano Martina, Chiloiro Sabrina, Doglietto Francesco, Olivi Alessandro, Lauretti Liverana

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To refine a reliable and reproducible intraoperative visual evoked potentials (iVEPs) monitoring protocol during endoscopic transsphenoidal surgery. To assess the reliability of baseline iVEPs in predicting preoperative visual status and perioperative iVEP variation in predicting postoperative visual outcome.

METHODS

Sixty-four patients harboring tumors of the pituitary region were included. All patients underwent endoscopic endonasal approach (EEA) with iVEPs monitoring, using a totally intravenous anesthetic protocol. Ophthalmological evaluation included visual acuity and visual field studies.

RESULTS

Preoperatively, visual acuity was reduced in 86% and visual field in 76.5% of cases. Baseline iVEPs amplitude was significantly correlated with preoperative visual acuity and visual field (p = 0.001 and p = 0.0004, respectively), confirming the reliability of the neurophysiological/anesthetic protocol implemented. Importantly, perioperatively the variation in iVEPs amplitude was significantly correlated with the changes in visual acuity (p < 0.0001) and visual field (p = 0.0013). ROC analysis confirmed that iVEPs are an accurate predictor of perioperiative visual acuity improvement, with a 100% positive predictive value in patients with preoperative vision loss.

CONCLUSIONS

iVEPs during EEA is highly reliable in describing preoperative visual function and can accurately predict postoperative vision improvement.

SIGNIFICANCE: iVEPs represent a promising resource for carrying out a more effective and safe endoscopic transsphenoidal surgery.

Для цитирования: Mattogno Pier Paolo, D'Alessandris Quintino Giorgio, Rigante Mario, Granata Giuseppe, Di Domenico Michele, Perotti Valerio, Montano Nicola, Giordano Martina, Chiloiro Sabrina, Doglietto Francesco, Olivi Alessandro, Lauretti Liverana. Reliability of intraoperative visual evoked potentials (iVEPs) in monitoring visual function during endoscopic transsphenoidal surgery.. Acta neurochirurgica. 2023. DOI: 10.1007/s00701-023-05778-1.