MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics16183024

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2026

Comparing Visual Outcomes Between Two Extended Depth-of-Focus Intraocular Lenses in an Asian Population.

Choo Jessica Q H, Tan Peng Y, Yang Younian, Wong Melissa H Y

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

To compare the visual outcomes between two extended depth-of-focus intraocular lenses (EDOF IOLs) in an Asian population.

Methods

This retrospective single-center study included patients with senile cataract undergoing cataract surgery with implantation of either TECNIS PureSee or AcrySof IQ Vivity IOL. Visual and refractive outcomes such as visual acuity (VA), manifest refraction, and mean refractive spherical equivalent were compared up to post-operative month 6. Contrast sensitivity and defocus curves were evaluated monocularly, as well as binocularly if both eyes had the same IOL implanted.

Results

Forty-nine eyes were evaluated-24 implanted with PureSee and 25 implanted with AcrySof IQ Vivity. The follow-up period was 6.4 ± 1.1 months in the PureSee group and 6.4 ± 1.0 months in the Vivity group (p = 1.0). There was no significant difference in postoperative visual outcomes at postoperative month 1 or 6. At post-operative month 6, unaided distance VA was 0.06 ± 0.10 and 0.08 ± 0.14 in the PureSee and Vivity groups, respectively (p = 0.519); unaided intermediate VA was 0.21 ± 0.05 and 0.18 ± 0.09, respectively (p = 0.192); and unaided near VA was 0.38 ± 0.12 and 0.38 ± 0.12, respectively (p = 0.842). Defocus and contrast sensitivity performance were broadly similar, except for Vivity's defocus being marginally better at 66 cm intermediate distance. At post-operative month 1, 69.2% of Vivity patients (n = 13) and 75.0% of PureSee patients (n = 4) denied haloes or glare.

Conclusions

Both EDOF IOLs demonstrated comparable visual performances.

Для цитирования: Choo Jessica Q H, Tan Peng Y, Yang Younian, Wong Melissa H Y. Comparing Visual Outcomes Between Two Extended Depth-of-Focus Intraocular Lenses in an Asian Population.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16183024.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.