BACKGROUND

Step activity monitors provide insight into the amount of physical activity prosthesis users conduct but not how they use their prosthesis. The purpose of this research was to help fill this void by developing and testing a technology to monitor bodily position and type of activity.

METHODS

Thin inductive distance sensors were adhered to the insides of sockets of a small group of transtibial prosthesis users, two at proximal locations and two at distal locations. An in-lab structured protocol and a semi-structured out-of-lab protocol were video recorded, and then participants wore the sensing system for up to 7 days. A data processing algorithm was developed to identify sit, seated shift, stand, standing weight-shift, walk, partial doff, and non-use. Sensed distance data from the structured and semi-structured protocols were compared against the video data to characterize accuracy. Bodily positions and activities during take-home testing were tabulated to characterize participants' use of the prosthesis.

FINDINGS: Sit and walk detection accuracies were above 95% for all four participants tested. Stand detection accuracy was above 90% for three participants and 62.5% for one participant. The reduced accuracy may have been due to limited stand data from that participant. Step count was not proportional to active use time (sum of stand, walk, and standing weight-shift times).

INTERPRETATION: Step count may provide an incomplete picture of prosthesis use. Larger studies should be pursued to investigate how bodily position and type of activity may facilitate clinical decision-making and improve the lives of people with lower limb amputation.

Для цитирования: Mertens Joseph C, Brzostowski Jacob T, Vamos Andrew, Allyn Katheryn J, Hafner Brian J, Friedly Janna L, DeGrasse Nicholas S, Ballesteros Daniel, Krout Adam, Larsen Brian G, Garbini Joseph L, Sanders Joan E. A novel portable sensor to monitor bodily positions and activities in transtibial prosthesis users.. Clinical biomechanics (Bristol, Avon). 2022. DOI: 10.1016/j.clinbiomech.2022.105741.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.