OBJECTIVES

The aim of this study was to assess the safety and efficacy of a new subxiphoid hybrid epicardial-endocardial atrial fibrillation (AF) ablation and left atrial appendage (LAA) ligation approach for the treatment of persistent AF.

BACKGROUND

Surgical hybrid ablation procedures have shown promise for maintaining sinus rhythm versus catheter ablation but are associated with increased periprocedural adverse events.

METHODS

Patients with symptomatic persistent AF (n = 33, mean age 64 ± 9 years, 25 men) who had antiarrhythmic drug therapy or prior catheter ablation was unsuccessful were referred for hybrid epicardial-endocardial AF ablation and LAA exclusion. LAA closure was confirmed by transesophageal echocardiographic Doppler flow and/or computed tomographic angiography 1 to 3 months post-ligation. The incidence of atrial tachycardia or AF recurrence, LAA closure, thromboembolic events, and post-operative complications were assessed.

RESULTS

All 33 patients underwent successful LAA ligation with epicardial ablation of the posterior left atrial wall, as well as endocardial pulmonary vein isolation and cavotricuspid isthmus ablation. Freedom from atrial tachycardia or AF was 91% (20 of 22 patients) at 6 months, 90% (18 of 20 patients) at 12 months, 92% (11 of 12 patients) at 18 months, and 92% (11 of 12) at 24 months. There were no acute periprocedural complications (<7 days). Thirty-day adverse events included 2 patients with pericardial effusion requiring pericardiocentesis and 1 incisional hernia repair. There were no long-term complications, strokes, or deaths. LAA ligation was complete in 27 of 33 subjects (82%), with 6 subjects having leaks of <5 mm.

CONCLUSIONS

Subxiphoid hybrid epicardial-endocardial ablation with LAA ligation is feasible, safe, and effective. Future prospective studies are needed to validate these initial findings.

Для цитирования: Ellis Christopher R, Badhwar Nitish, Tschopp David, Danter Matthew, Jackson Gregory G, Kerendi Faraz, Walters Tomas, Fang Qizhi, Deuse Tobias, Beygui Ramin, Lee Randall J. Subxiphoid Hybrid Epicardial-Endocardial Atrial Fibrillation Ablation and LAA Ligation: Initial Sub-X Hybrid MAZE Registry Results.. JACC. Clinical electrophysiology. 2020. DOI: 10.1016/j.jacep.2020.06.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.