Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2025

Heart substructure exposure during left breast cancer radiotherapy: a dosimetric comparison between hybrid VMAT and 3DCRT in free breathing and deep inspiration breath hold (DIBH).

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Romera-Martínez Ingrid, Cancio Irene Oliveras, Buxó Maria, Martínez Joan, Fuentes-Raspall Rafael, Urién Arantxa Eraso, Vilanova Joan Carles

Аннотация

BACKGROUND AND PURPOSE: Radiotherapy plays a pivotal role in breast cancer treatment. Incidental irradiation of the heart can cause cardiac toxicity. We conducted a dosimetric comparison between Hybrid VMAT (H-VMAT) and 3D Conformal Radiotherapy (3DCRT) in both Free Breathing (FB) and Deep inspiration breath hold (DIBH) techniques for left-sided breast cancer patients.

MATERIALS AND METHODS: Thirty-seven patients underwent CT scans in both FB and DIBH positions. Heart substructures were delineated following established guidelines. Subsequently, 3DCRT and H-VMAT plans were generated for each patient in both breath techniques. The dosimetric parameters of heart and its cavities were analysed: Dmean(Gy) and V5Gy(%) for heart substructures, Dmean(Gy), V25Gy(%) and V30Gy(cm3) for heart and D98%(%), D2%(%), D50%(%) and V95%(%) or V90%(%) for PTVs. Statistical analyses were performed.

RESULTS: The analysis revealed statistically significant differences for the heart, and its cavities. The 3DCRT plans generated in DIBH offered a statistically significant lower dose for the heart and its substructures compared to the other techniques. When comparing PTV dosimetry, the H-VMAT plans showed an increase D98%(%) and a decrease D2%(%) relative to the 3DCRT plans, for both breathing techniques employed.

CONCLUSION: Our study demonstrates significant differences in the dosimetric outcomes for the heart substructures among the four evaluated techniques, with 3DCRT in DIBH yielding the lowest parameters for most substructures. Although H-VMAT provided superior target coverage, it resulted in greater low doses incidental exposure of the heart substructures. Notably, 3DCRT plans in the DIBH setting exhibited lower doses compared to H-VMAT in FB, supporting its preferential use for minimising cardiac exposure.