MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12094-025-03943-9

Медицинская библиотека · Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2025

Heart substructure exposure during left breast cancer radiotherapy: a dosimetric comparison between hybrid VMAT and 3DCRT in free breathing and deep inspiration breath hold (DIBH).

Romera-Martínez Ingrid, Cancio Irene Oliveras, Buxó Maria, Martínez Joan, Fuentes-Raspall Rafael, Urién Arantxa Eraso, Vilanova Joan Carles

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Radiotherapy plays a pivotal role in breast cancer treatment. Incidental irradiation of the heart can cause cardiac toxicity. We conducted a dosimetric comparison between Hybrid VMAT (H-VMAT) and 3D Conformal Radiotherapy (3DCRT) in both Free Breathing (FB) and Deep inspiration breath hold (DIBH) techniques for left-sided breast cancer patients.

MATERIALS AND

METHODS

Thirty-seven patients underwent CT scans in both FB and DIBH positions. Heart substructures were delineated following established guidelines. Subsequently, 3DCRT and H-VMAT plans were generated for each patient in both breath techniques. The dosimetric parameters of heart and its cavities were analysed: Dmean(Gy) and V5Gy(%) for heart substructures, Dmean(Gy), V25Gy(%) and V30Gy(cm3) for heart and D98%(%), D2%(%), D50%(%) and V95%(%) or V90%(%) for PTVs. Statistical analyses were performed.

RESULTS

The analysis revealed statistically significant differences for the heart, and its cavities. The 3DCRT plans generated in DIBH offered a statistically significant lower dose for the heart and its substructures compared to the other techniques. When comparing PTV dosimetry, the H-VMAT plans showed an increase D98%(%) and a decrease D2%(%) relative to the 3DCRT plans, for both breathing techniques employed.

CONCLUSION

Our study demonstrates significant differences in the dosimetric outcomes for the heart substructures among the four evaluated techniques, with 3DCRT in DIBH yielding the lowest parameters for most substructures. Although H-VMAT provided superior target coverage, it resulted in greater low doses incidental exposure of the heart substructures. Notably, 3DCRT plans in the DIBH setting exhibited lower doses compared to H-VMAT in FB, supporting its preferential use for minimising cardiac exposure.

Для цитирования: Romera-Martínez Ingrid, Cancio Irene Oliveras, Buxó Maria, Martínez Joan, Fuentes-Raspall Rafael, Urién Arantxa Eraso, Vilanova Joan Carles. Heart substructure exposure during left breast cancer radiotherapy: a dosimetric comparison between hybrid VMAT and 3DCRT in free breathing and deep inspiration breath hold (DIBH).. Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico. 2025. DOI: 10.1007/s12094-025-03943-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.