DOI 10.1016/j.radonc.2025.110917

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2025

Radiographic classification of mandibular osteoradionecrosis: A blinded prospective multi-disciplinary interobserver diagnostic performance study.

Kaffey Zaphanlene, Mirbahaeddin Sarah, Wahid Kareem, Kamel Serageldin, Vouffo Michael, Otun Adegbenga O, Belal Zayne, Aponte Wesson Ruth A, Carriere Patrick P, Dede Cem, Maniakas Anastasios, Goepfert Ryan P, Garden Adam S, Lee Anna, Choi Karen Y, Christensen Joani M, Lincoln Christie, Manzar Gohar S, Dudzinski Stephanie O, Thomas Rehema, Mehrens Hunter, Cardoso Richard C, Schellingerhout Dawid, Watson Erin, Chen Melissa M, Lai Stephen Y, Fuller Clifton D, Moreno Amy C, Humbert-Vidan Laia, MD Anderson Head and Neck Cancer Symptom Working Group

СтатьяВалидационное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND & PURPOSE: Osteoradionecrosis (ORN) of the jaw is a severe complication affecting up to 15% of head and neck cancer patients treated with radiotherapy. The ClinRad system, endorsed by ASCO/ISOO/MASCC, incorporates radiographic features for ORN severity classification, but variability in imaging use and specialty expertise may impact diagnostic accuracy. This study benchmarks physician performance in diagnosing and staging ORN across specialties and imaging modalities.

MATERIALS &

METHODS

A retrospective diagnostic validation study was conducted at MD Anderson Cancer Center, involving 20 physicians from oral oncology, radiation oncology, surgery, and neuroradiology. Participants reviewed 85 de-identified imaging sets (CT and orthopantogram (OPG)) from 30 patients with confirmed ORN, diagnosing and staging cases using the ClinRad system. ROC analysis assessed diagnostic accuracy, while intra- and inter-observer agreement was measured using Cohen's and Fleiss kappa statistics.

RESULTS

Paired CT-OPG imaging significantly improved diagnostic performance across specialties (p < 0.001), with AUC values ranging from 0.79 (residents) to 0.98 (surgeons). However, inter- and intra-rater agreement remained low, with median Fleiss kappa values of 0.22, 0.13, and 0.05 for ClinRad stages 0/1, 2, and 3, respectively. No specialty demonstrated significantly superior diagnostic accuracy (p > 0.05).

CONCLUSION

This study establishes a benchmark for radiographic ORN detection, revealing diagnostic variability across specialties. Findings emphasize the need for standardized imaging protocols, interdisciplinary training, and multimodal imaging to improve diagnostic accuracy.

Для цитирования: Kaffey Zaphanlene, Mirbahaeddin Sarah, Wahid Kareem, Kamel Serageldin, Vouffo Michael, Otun Adegbenga O, Belal Zayne, Aponte Wesson Ruth A, Carriere Patrick P, Dede Cem, Maniakas Anastasios, Goepfert Ryan P, Garden Adam S, Lee Anna, Choi Karen Y, Christensen Joani M, Lincoln Christie, Manzar Gohar S, Dudzinski Stephanie O, Thomas Rehema, Mehrens Hunter, Cardoso Richard C, Schellingerhout Dawid, Watson Erin, Chen Melissa M, Lai Stephen Y, Fuller Clifton D, Moreno Amy C, Humbert-Vidan Laia, MD Anderson Head and Neck Cancer Symptom Working Group. Radiographic classification of mandibular osteoradionecrosis: A blinded prospective multi-disciplinary interobserver diagnostic performance study.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2025. DOI: 10.1016/j.radonc.2025.110917.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.