m+Medelevator.RU
← Поиск публикаций
Journal of hepatology · 2020

Update of the simplified criteria for autoimmune hepatitis: Evaluation of the methodology for immunoserological testing.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Galaski Johanna, Weiler-Normann Christina, Schakat Miriam, Zachou Kalliopi, Muratori Paolo, Lampalzer Sibylle, Haag Friedrich, Schramm Christoph, Lenzi Marco, Dalekos George N, Lohse Ansgar W

Аннотация

BACKGROUND & AIMS: The simplified criteria for the diagnosis of autoimmune hepatitis (AIH) include immunofluorescence testing (IFT) of antinuclear and smooth muscle autoantibodies (ANA and SMA) on rodent tissue sections. We aimed to establish scoring criteria for the implementation of ANA IFT on human epithelioma-2 (HEp-2) cells and ELISA-based testing.

METHODS: ANA and SMA reactivity of 61 AIH sera and 72 non-alcoholic fatty liver disease controls were separately assessed on tissue sections and HEp-2 cells to compare the diagnostic value at increasing titers. A total of 113 patients with AIH at diagnosis and 202 controls from 3 European centers were assessed by IFT as well as 3 different commercially available ANA ELISA and 1 anti-F-actin ELISA.

RESULTS: ANA assessment by IFT on liver sections had 83.6% sensitivity and 69.4% specificity for AIH at a titer of 1:40. On HEp-2 cells, sensitivity and specificity were 75.4% and 73.6%, respectively, at an adjusted titer of 1:160. Area under the curve (AUC) values of ANA ELISA ranged from 0.70-0.87, with ELISA coated with HEp-2 extracts in addition to selected antigens performing significantly better. SMA assessment by IFT had the highest specificity for the SMA-VG/T pattern and anti-microfilament reactivity on HEp-2 cells. ELISA-based anti-F-actin evaluation was a strong predictor of AIH (AUC 0.88) and performed better than SMA assessment by IFT (AUC 0.77-0.87).

CONCLUSION: At adjusted cut-offs, both ANA IFT using HEp-2 cells and ELISA-based autoantibody evaluation for ANA and SMA are potential alternatives to tissue-based IFT for the diagnosis of AIH.

LAY SUMMARY: Autoantibodies are a hallmark of autoimmune hepatitis and are traditionally tested for by immunofluorescence assays on rodent tissue sections. Herein, we demonstrate that human epithelioma cells can be used as a reliable substrate for immunofluorescence testing. ELISA-based testing is also a potentially reliable alternative for autoantibody assessment in autoimmune hepatitis. We propose the implementation of these testing methods into the simplified criteria for the diagnosis of autoimmune hepatitis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты