Incidence, indications and predicting factors of permanent pacemaker implantation after transcatheter aortic valve implantation: A retrospective study.

Becker Mathieu, Blangy Hugues, Folliguet Thierry, Villemin Thibault, Freysz Luc, Luc Amandine, Maureira Pablo, Popovic Batric, Olivier Arnaud, Sadoul Nicolas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

As the number of transcatheter aortic valve implantation (TAVI) procedures is constantly increasing, it is important to consider common complications, such as pacemaker (PM) implantation, and their specific risk factors.

AIMS: Echocardiographic, computed tomography and electrocardiographic data were analysed to determine the predicting factors, if any, associated with PM implantation.

METHODS

This retrospective study included patients referred to Nancy University Hospital for a TAVI procedure from January 2013 to December 2015. Both Medtronic CoreValve and Edwards SAPIEN valves were implanted. Patients with preprocedurally implanted PMs and/or referred from another institution were excluded.

RESULTS

Of 208 TAVI patients, 23 had a pre-existing PM and were excluded. A new PM was required in 38 patients (20.5%). Pre-existing right bundle branch block (RBBB), the use of the Medtronic CoreValve and large prostheses were identified as predictors of PM implantation (P=0.0361, P=0.0004 and P=0.0019, respectively). Using logistic regression, predictors of PM implantation included first-degree atrioventricular block (odds ratio 3.7, 95% confidence interval 1.5-9.1; P=0.0054) and large aortic annulus diameter in echocardiography (odds ratio 1.2, 95% confidence interval 1-1.4; P=0.0447), with a threshold of 24.1mm. For the combination of preTAVI PR duration >220ms and QRS duration >120ms, the positive predictive value for PM implantation reached 80%.

CONCLUSION

Use of the Medtronic CoreValve, RBBB and first-degree atrioventricular block are major risk factors for post-TAVI PM implantation. In addition, large aortic annulus and large valvular prosthesis are independent risk factors for PM implantation. The combination of preTAVI prolonged PR interval and increased QRS duration could be used as a marker for periprocedural PM implantation.

Для цитирования: Becker Mathieu, Blangy Hugues, Folliguet Thierry, Villemin Thibault, Freysz Luc, Luc Amandine, Maureira Pablo, Popovic Batric, Olivier Arnaud, Sadoul Nicolas. Incidence, indications and predicting factors of permanent pacemaker implantation after transcatheter aortic valve implantation: A retrospective study.. Archives of cardiovascular diseases. 2017. DOI: 10.1016/j.acvd.2017.03.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.