MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-016-0684-z

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016

Mechanical dyssynchrony according to validated cut-off values using gated SPECT myocardial perfusion imaging.

Aguadé-Bruix Santiago, Romero-Farina Guillermo, Candell-Riera Jaume, Pizzi María N, García-Dorado David

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study was to establish different degrees of mechanical dyssynchrony according to validated cut-off (CO) values of myocardial perfusion gated SPECT phase analysis parameters (SD, standard deviation; B, bandwidth; S, skewness; K, kurtosis).

METHODS

Using Emory Cardiac Toolbox™, we prospectively analyzed 408 patients (mean age 64.1 years, 26.7% female), divided into a control group of 150 normal subjects and a validation group of 258 patients (left bundle branch block: 17.8%, right bundle branch block: 8.9%. atrial fibrillation: 16.3%, coronary revascularization: 30%, dilated cardiomyopathy: 7.4%. valvulopathies: 2.7%, ischemic test: 45.3%) with ischemic and non-ischemic cardiac diseases, by means of phase analysis.

RESULTS

Agreement of CO values (SD > 18.4°; B > 51°; S ≤ 3.2; K ≤ 9.3) used to discriminate between normal subjects and patients was strong (c-statistic 0.9; 95% CI 0.98-0.99). Four degrees of dyssynchrony were found according to the number of abnormal phase parameters. All patients with mechanical and electrical criteria for cardiac resynchronization therapy (CCRT) (n: 82) had Grade 2 to 4 (two to four abnormal phase parameters). Agreement of CO values (SD > 40.2°; B > 132°; S ≤ 2.3; K ≤ 4.6) used to discriminate between patients with and without CCRT was strong (c-statistic 0.8; 95% CI 0.79-0.87) but 12% of patients with CCRT did not have any of these abnormal phase parameters.

CONCLUSIONS

The discriminatory capacity of gated SPECT phase analysis parameters between normal subjects and patients, and between patients with and without CCRT, is very good, making it possible to define different degrees of mechanical dyssynchrony.

Для цитирования: Aguadé-Bruix Santiago, Romero-Farina Guillermo, Candell-Riera Jaume, Pizzi María N, García-Dorado David. Mechanical dyssynchrony according to validated cut-off values using gated SPECT myocardial perfusion imaging.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2016. DOI: 10.1007/s12350-016-0684-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.