MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2016.07.044

Медицинская библиотека · The Annals of thoracic surgery · 2016

Conduction Disorders After Sutureless Aortic Valve Replacement.

Bouhout Ismail, Mazine Amine, Rivard Lena, Ghoneim Aly, El-Hamamsy Ismail, Lamarche Yoan, Carrier Michel, Demers Philippe, Bouchard Denis

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Sutureless self-expandable aortic bioprostheses rely on radial forces for stabilization, raising concern that these devices may increase the risk of postoperative conduction disease. The purpose of this study was to determine the incidence of conduction disorders after sutureless aortic valve replacement (AVR) with the Perceval S (Sorin Group, Saluggia, Italy) bioprosthesis.

METHODS

Between June 2011 and March 2013, 108 consecutive patients underwent sutureless AVR with the Perceval S prosthesis. Six patients (6%) had a permanent pacemaker (PPM) preoperatively and were excluded from the present study. Mean electrocardiographic follow-up was 14.6 ± 6.0 months.

RESULTS

Mean age was 79.2 ± 4.8 years (52% female). During the postoperative period, 34 patients (34%) had first-degree atrioventricular block, 2 (2%) had Mobitz-II atrioventricular block, and 16 (16%) had complete atrioventricular block. New-onset left bundle branch block and right bundle branch block were observed in 33 patients (33%) and 22 patients (22%), respectively. Inhospital postoperative PPM implantation was required in 23 patients (23%). Preoperative aortic valve area, age more than 85 years, and preoperative right bundle branch block were found to be independently associated with inhospital PPM implantation or new-onset postoperative conduction disorder. At follow-up, 3 more patients (3%) underwent PPM implantation. The cumulative incidences of PPM dependency and ventricular pacing more than 25% of the time were 18% ± 11% and 21% ± 10%, respectively, at 18 months.

CONCLUSIONS

In the present study, the postoperative PPM implantation rate (23%) after sutureless AVR with the Perceval S prosthesis was high. Surgical strategies aimed at mitigating this risk should be further investigated.

Для цитирования: Bouhout Ismail, Mazine Amine, Rivard Lena, Ghoneim Aly, El-Hamamsy Ismail, Lamarche Yoan, Carrier Michel, Demers Philippe, Bouchard Denis. Conduction Disorders After Sutureless Aortic Valve Replacement.. The Annals of thoracic surgery. 2016. DOI: 10.1016/j.athoracsur.2016.07.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.