Obesity surgery · 2004
Laparoscopic biliopancreatic diversion with duodenal switch: three different duodeno-ileal anastomotic techniques and initial experience.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Weiner R A, Blanco-Engert R, Weiner S, Pomhoff I, Schramm M
Аннотация
BACKGROUND: The duodenal switch (DS) is a variant of the biliopancreatic diversion (BPD) for surgical treatment of morbid obesity. Absence of dumping syndrome leads to a high quality of life in these patients. The complexity of the laparoscopic BPD-DS is high, and the technical aspects of the duodeno-ileostomy are still under consideration.
MATERIALS AND METHODS: Laparoscopic BPD-DS is described, with early surgical outcomes of 63 patients reported. We used 3 different techniques for creation of the duodeno-ileostomy, which were compared.
RESULTS: 2 staple-line leaks at the gastric sleeve and 1 anastomotic leak after circular stapling of the duodeno-ileostomy occurred. In the same patient with the leak, a marginal ulcer was registered 4 months after surgery. There were no differences in the operating-time between the 3 groups. The combined linear stapled and totally hand-sewn anastomosis were the safest methods to perform the duodeno-ileostomy. Local wound infection at a trocar site (insertion of the circular stapler) was the most common local complication, occurring in 3 patients after using the circular stapling technique only. Postoperative stay was 4 to 8 days, except for the 3 patients with complications.
CONCLUSION: Laparoscopic BPD-DS is an advanced, complex and feasible technique in bariatric surgery. The combined linear stapled and total hand-sewn anastomosis are not only the technically easiest procedures to perform, but also appear to be the safest techniques.
MATERIALS AND METHODS: Laparoscopic BPD-DS is described, with early surgical outcomes of 63 patients reported. We used 3 different techniques for creation of the duodeno-ileostomy, which were compared.
RESULTS: 2 staple-line leaks at the gastric sleeve and 1 anastomotic leak after circular stapling of the duodeno-ileostomy occurred. In the same patient with the leak, a marginal ulcer was registered 4 months after surgery. There were no differences in the operating-time between the 3 groups. The combined linear stapled and totally hand-sewn anastomosis were the safest methods to perform the duodeno-ileostomy. Local wound infection at a trocar site (insertion of the circular stapler) was the most common local complication, occurring in 3 patients after using the circular stapling technique only. Postoperative stay was 4 to 8 days, except for the 3 patients with complications.
CONCLUSION: Laparoscopic BPD-DS is an advanced, complex and feasible technique in bariatric surgery. The combined linear stapled and total hand-sewn anastomosis are not only the technically easiest procedures to perform, but also appear to be the safest techniques.