Медицинская библиотека · Archivos espanoles de urologia · 2012

Surgical treatment of vaginal prolapse with Prolift® mesh in patients with risk of recurrence.

Martínez-Franco Eva, Amat-Tardiu Lluís, Rodríguez-Mias Núria, Cortés-Laguna Laura, Laïlla-Vicens Josep María

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this paper is to analyze the results obtained in pelvic floor surgery using a non-absorbable mesh in selected patients with risk factors of recurrent prolapse.

METHODS

Case series including a total of 76 patients who were surgically treated for severe genital prolapse from July 2005 to December 2009, with risk factors for recurrence of genital prolapse.

RESULTS

We detected 3 cases (6.8%) of symptomatic prolapse recurrence and 6 cases (13.6%) of prolapse of another compartment in the anterior Prolift® group. In the posterior Prolift® group there were no recurrences but there were 2 cases (10.52%) of prolapse of another compartment. In the total Prolift® group, there were 2 cases (16.6%) of symptomatic prolapse recurrence. As for de novo urgency, there were a total of 4 cases (5.33%), 3 in the anterior Prolift® group and 1 in the total Prolift® group. We did not detect any case of severe pain in the pelvis or mesh insertion points that required reoperation due to persistence.

CONCLUSIONS

The use of mesh in pelvic floor reconstructive surgery in selected patients with risk factors for recurrence is a good treatment option to prevent or attempt to reduce the recurrence or reoperation rates currently described.

Для цитирования: Martínez-Franco Eva, Amat-Tardiu Lluís, Rodríguez-Mias Núria, Cortés-Laguna Laura, Laïlla-Vicens Josep María. Surgical treatment of vaginal prolapse with Prolift® mesh in patients with risk of recurrence.. Archivos espanoles de urologia. 2012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.