Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2012

Prediction of distal embolization during percutaneous coronary intervention for unstable plaques with grayscale and integrated backscatter intravascular ultrasound.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shibuya Masahiko, Okamura Atsunori, Hao Hiroyuki, Date Motoo, Higuchi Yoshiharu, Nagai Hiroyuki, Ozawa Makito, Masuyama Tohru, Iwakura Katsuomi, Fujii Kenshi

Аннотация

OBJECTIVES: We performed microscopic examination of the debris collected by a distal protection device and investigated the usefulness of grayscale and integrated backscatter intravascular ultrasound (IB-IVUS) for the prediction of distal embolization during percutaneous coronary intervention (PCI) in cases of unstable angina.

BACKGROUND: The prediction of distal embolization during PCI has not been studied in depth because assessment of distal embolization is difficult.

METHODS: We prospectively studied 39 consecutive patients with unstable angina who underwent PCI with a filter distal protection device. The preprocedural plaque volume at target lesions was measured with grayscale IVUS and plaque characteristics were assessed with IB-IVUS. We performed microscopic examination of the particles collected by the distal protection device.

RESULTS: There was a significant correlation between the plaque volume and the number of the collected particles >100 μm in diameter (r = 0.48, P = 0.0034). Filter no-reflow (FNR) phenomenon was found in nine patients. The plaque volume was significantly greater (355 ± 133 mm(3) vs. 199 ± 90 mm(3) , P = 0.0004), and the lipid ratio was significantly higher (29.3 ± 4.3% vs. 26.1 ± 4.3 P = 0.045) in the FNR group compared with the non-FNR group. Multivariate logistic regression analysis showed that the plaque volume was an independent predictor of FNR phenomenon.

CONCLUSIONS: Although tissue characterization of IB-IVUS may provide additional information for distal embolization, plaque volume is the only significant predictor of distal embolization during PCI.