MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00192-011-1646-2

Медицинская библиотека · International urogynecology journal · 2012

Evidence of a functional effect of transient transurethral catheterization on micturition in women.

Suskind Anne M, Smith Phillip P

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION AND HYPOTHESIS: The objective of this study is to evaluate the effect of transient catheterization on uroflow parameters.

METHODS

Consenting women (ages 18-90) provided an uninstrumented uroflow pre- and post-indicated in urodynamic procedures. Voided volume, Qmax, and Qave were recorded for both uninstrumented uroflows. Uroflow curves were classified as "normal" or "abnormal." Pre- and post-urodynamic uroflow data were compared.

RESULTS

Thirty-five patients were included in the study. There was a statistically significant decrease in Qave from the pre- to the post-urodynamic uroflows from 14.71 to 10.55 ml/s (p = 0.012). Additionally, 28.6% of uroflow tracing patterns changed from "normal" to "abnormal," whereas only one (2.9%) changed from "abnormal" to "normal" (p = 0.031).

CONCLUSIONS

This study showed a degradative effect of transient catheterization on uroflow parameters, suggesting that catheterization may cause more than simply a passive obstructive effect. Urethral stimulation due to catheterization may perturb detrusor urethral function, altering voiding and possibly filling performance.

Для цитирования: Suskind Anne M, Smith Phillip P. Evidence of a functional effect of transient transurethral catheterization on micturition in women.. International urogynecology journal. 2012. DOI: 10.1007/s00192-011-1646-2.