DOI 10.1016/j.urology.2011.11.002
The effect of extralumenal safety wires on ureteral injury and insertion force of ureteral access sheaths: evaluation using an ex vivo porcine model.
Аннотация
OBJECTIVE
To evaluate the effect that a safety wire (SW) had on insertion force and direct ureteral trauma using ureteral access sheaths (UAS) in an ex vivo porcine model.
MATERIAL AND
METHODS
UASs were advance into 20 fresh ex vivo porcine kidney-ureters, either with or without SWs. The average and max force of insertion were recorded. Retrograde saline injection was used to identify the presence of lacerations.
RESULTS
For SW vs no SW, the mean insertion force (1.79 vs 0.67, P = .0003, respectively) and max insertion force (2.29 kg vs 1.00, P = .0007) was greater in the SW group. There were 9 lacerations, 6 of which were partial and 3 complete. Of the partial injuries, 2 were in the no SW group and 4 were in the SW group. Of the complete lacerations, 2 occurred in the no SW group and 1 in the SW group. However, there was no significant difference in the total number of lacerations (P = 1.00), the number of partial lacerations (P = .628), or the number of complete lacerations (P = 1.00) between the 2 groups.
CONCLUSIONS
The use of an SW significantly increases the force required to insert a UAS; however, it does not appear to affect the force or the degree of ureteral injury.
Другие публикации по теме
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.