Accuracy of a urinary catheter surveillance protocol.
Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Burns Allison C, Petersen Nancy J, Garza Armandina, Arya Monisha, Patterson Jan E, Naik Aanand D, Trautner Barbara W
Аннотация
BACKGROUND: Many hospitals are increasing surveillance for catheter-associated urinary tract infections, which requires documentation of urinary catheter device-days. However, device-days are usually obtained by chart review or nursing reports. The aim of this study was to demonstrate that chart review can provide accurate urinary catheter data compared with physical inspection of the urinary catheter at the bedside.
METHODS: We compared 2 methods for collecting urinary catheter data over a 6-month period on 10 wards at our VA hospital. For the chart reviews, we created a daily bed-occupancy roster from the electronic medical record. Catheter data were extracted from the daily progress notes for each patient using a standardized review process. Bedside reviews were conducted by visiting the ward and verifying the presence and type of urinary catheters. Agreement between the 2 methods was calculated.
RESULTS: We obtained urinary catheter data by both methods in 621 cases. The presence or type of urinary catheter differed between chart and bedside review in only 10 cases (1.6%). Chart review had a sensitivity of 100%, a specificity of 97.7%, raw agreement of 98.4%, and a κ value of 0.96.
CONCLUSIONS: Individual chart review in the electronic medical record provided very accurate data on urinary catheter use.
METHODS: We compared 2 methods for collecting urinary catheter data over a 6-month period on 10 wards at our VA hospital. For the chart reviews, we created a daily bed-occupancy roster from the electronic medical record. Catheter data were extracted from the daily progress notes for each patient using a standardized review process. Bedside reviews were conducted by visiting the ward and verifying the presence and type of urinary catheters. Agreement between the 2 methods was calculated.
RESULTS: We obtained urinary catheter data by both methods in 621 cases. The presence or type of urinary catheter differed between chart and bedside review in only 10 cases (1.6%). Chart review had a sensitivity of 100%, a specificity of 97.7%, raw agreement of 98.4%, and a κ value of 0.96.
CONCLUSIONS: Individual chart review in the electronic medical record provided very accurate data on urinary catheter use.