Practical laboratory medicine · 2021
The "EPiQ"-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Millius Laura, Riedo Erwin, Caron Thierry, Belissent Juliette, Fellay Benoît, Ribordy Vincent, Magnin Jean-Luc
Аннотация
BACKGROUND: Hemolytic blood samples are the number one cause for specimen rejection at emergency departments. Triggered by unsuitable blood sampling material or incorrect handling and a related strong vacuum force, hemolytic samples often must be retaken. The objective of this study was to assess whether correct manual aspiration using S-Monovette® could reduce the number of hemolytic samples.
METHODS: Between January and April 2019, a head-to-head study was conducted. Whereas in the first eight weeks, all specimens were collected using Vacutainer®, in the second eight weeks, blood was taken using S-Monovette® in aspiration mode. Specimens were categorized into five classes (0-30, 31-50, 51-75, 76-100, and 101+ mg/dl of cell-free hemoglobin) and for the statistical analyses, all samples exceeding 30 mg/dl were classified as hemolytic.
RESULTS: Data were collected on 4794 blood specimens (Vacutainer®: 2634 samples, S-Monovette®: 2160 samples). While the percentage of non-hemolytic samples (HI of 0-30 mg/dl) was substantially higher for specimens drawn by S-Monovette® (95.7 %) than Vacutainer® (83.0 %), the opposite was true for all HI categories above 30 mg/dl. Importantly, the reduction of hemolytic samples took place immediately following the imposition of S-Monovette® and remained stable at a low level until the end of the study.
CONCLUSIONS: Based on our results, we conclude that switching to S-Monovette® in manual aspiration mode in the blood sampling process could be highly beneficial, not only from a financial point of view, but also with regards to reducing unnecessary tasks and stress for nursing staff and improving patient outcome overall.
METHODS: Between January and April 2019, a head-to-head study was conducted. Whereas in the first eight weeks, all specimens were collected using Vacutainer®, in the second eight weeks, blood was taken using S-Monovette® in aspiration mode. Specimens were categorized into five classes (0-30, 31-50, 51-75, 76-100, and 101+ mg/dl of cell-free hemoglobin) and for the statistical analyses, all samples exceeding 30 mg/dl were classified as hemolytic.
RESULTS: Data were collected on 4794 blood specimens (Vacutainer®: 2634 samples, S-Monovette®: 2160 samples). While the percentage of non-hemolytic samples (HI of 0-30 mg/dl) was substantially higher for specimens drawn by S-Monovette® (95.7 %) than Vacutainer® (83.0 %), the opposite was true for all HI categories above 30 mg/dl. Importantly, the reduction of hemolytic samples took place immediately following the imposition of S-Monovette® and remained stable at a low level until the end of the study.
CONCLUSIONS: Based on our results, we conclude that switching to S-Monovette® in manual aspiration mode in the blood sampling process could be highly beneficial, not only from a financial point of view, but also with regards to reducing unnecessary tasks and stress for nursing staff and improving patient outcome overall.