MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2020.02.020

Медицинская библиотека · The Annals of thoracic surgery · 2020

Three-Dimensional Modeling of Surgically Implanted Stent-Based Valves in the Mitral Position in Children.

Choi Perry S, Nam Hannah H, Lasso Andras, Herz Christian, Drouin Simon, Harrild David M, Quartermain Michael, Fichtinger Gabor, Mascio Christopher E, Emani Sitaram, Jolley Matthew A

СтатьяПоддержка исследования: вне правительства СШАVideo-Audio MediaПеревод пока не подготовлен

Аннотация

PURPOSE: In children with a mitral annulus too small to accommodate traditional prostheses, surgical implantation of stent-based valves is a promising option. However no reliable preoperative methods exist to guide patient selection, device sizing, and positioning. We describe a novel methodology to visualize and quantify device fit in 3-dimensional echocardiogram (3DE)-derived heart models.

DESCRIPTION: Heart models were created from existing preoperative 3DEs using custom software. Valve models were virtually implanted into the models, and both device fit and left ventricular outflow tract (LVOT) area were quantified.

EVALUATION: The 3DEs of 3 patients who underwent Melody valve placement in the mitral position were retrospectively modeled: 1 with LVOT obstruction, 1 with perivalvar leak, and 1 without complications. In all cases 2-dimensional measurements underestimated 3D annular dimensions, and the patient with clinical LVOT obstruction had the lowest predicted LVOT area-to-aortic area ratio (0.5).

CONCLUSIONS

3DE-based preoperative modeling of surgical implantation of stent-based valves in the mitral position may improve quantification of mitral valve dimensions and inform risk stratification for potential LVOT obstruction.

Для цитирования: Choi Perry S, Nam Hannah H, Lasso Andras, Herz Christian, Drouin Simon, Harrild David M, Quartermain Michael, Fichtinger Gabor, Mascio Christopher E, Emani Sitaram, Jolley Matthew A. Three-Dimensional Modeling of Surgically Implanted Stent-Based Valves in the Mitral Position in Children.. The Annals of thoracic surgery. 2020. DOI: 10.1016/j.athoracsur.2020.02.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.