Аннотация

PURPOSE: To assess the outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) via a sclerocorneal frown incision.

STUDY

DESIGN

Retrospective comparative study.

METHODS

The outcomes of Descement stripping endothelial keratoplasty (DSAEK) were retrospectively compared between 36 patients (36 eyes) who underwent surgery via a 3.8-mm frown incision (frown incision group) and 20 patients (20 eyes) who underwent surgery via a 4.6-mm straight incision (straight incision group). In all patients, an NS Endo-Inserter was used as the graft inserter and the incision for a frown incision was via the superior sclerocorneal site and for the straight incision via the temporal cornea. DSAEK was performed by the standard technique, except for the incision. At 1 year after surgery, the two groups were compared with respect to the visual acuity, decrease of corneal endothelial cell density, the severity of corneal astigmatism (diopters), the number of sutures for wound closure, and intraoperative/postoperative complications.

RESULTS

There was no significant difference between the two groups in terms of postoperative visual acuity, corneal astigmatism, and intraoperative/postoperative complications one year after surgery. On the other hand, the number of sutures required for wound closure was 1.13 ± 0.42 in the frown incision group, whereas in the straight incision group, it was 3.20 ± 0.40, showing a significant difference (P<0.001). In addition, there was no decreased corneal endothelial cell density associated with the reduction in incision width.

CONCLUSIONS

A sclerocorneal frown incision is useful for performing DSAEK with an NS Endo-Inserter as it does not affect endothelial cell loss despite its short incision width.

Для цитирования: Nakatani Satoru, Yamaguchi Masahiro, Iwamoto Satoshi. Descemet stripping automated endothelial keratoplasty via a frown incision.. Japanese journal of ophthalmology. 2024. DOI: 10.1007/s10384-023-01038-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.