MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.118787

Медицинская библиотека · Biosensors & bioelectronics · 2026

Ultrasensitive, robust, and selective detection of hepatitis B surface antigen enabled by vertical organic electrochemical transistor.

Aftab Saima, Xie Miao, Zhou Jinhao, Cheng Yuhua, Zhao Dan, Huang Wei

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

Early detection of hepatitis B virus (HBV) is essential for effective diagnosis and disease management. Hepatitis B surface antigen (HBsAg) is a key biomarker widely used for HBV screening. In this study, we report a vertical organic electrochemical transistor (vOECT)-based biosensor for label-free detection of HBsAg. The device employs a gold gate electrode functionalized with monoclonal HBV antibodies via carbodiimide coupling, providing covalent binding sites for the selective capture of HBsAg. Surface modification and immobilization processes are confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. The biosensor showed a wide linear detection range upon HBsAg binding from 100 pg/mL to 5000 ng/mL with a low detection limit of 42.7 fg/mL. Reproducibility tests showed relative standard deviation (RSD) values of 2.40% and 3.03% for 5.0 ng/mL and 5 μg/mL HBsAg, respectively, indicating high consistency across independently fabricated devices. The biosensor also exhibited strong selectivity against common biological interferents, including bilirubin, recombinant human serum albumin, carcinoembryonic antigen, creatinine, glucose and haemoglobin. Furthermore, stability studies show that more than 98% of the original response is retained after two weeks. These results highlight the potential of the vOECT platform as a sensitive, reliable and compact biosensing strategy for point-of-care HBV diagnostics.

Для цитирования: Aftab Saima, Xie Miao, Zhou Jinhao, Cheng Yuhua, Zhao Dan, Huang Wei. Ultrasensitive, robust, and selective detection of hepatitis B surface antigen enabled by vertical organic electrochemical transistor.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.118787.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.