Case report: reversible mitral regurgitation and congestive heart failure complicating thyrotoxicosis.

Cavros N G, Old W D, Castro F D, Estep H L

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Congestive heart failure is a relatively uncommon manifestation of thyrotoxic heart disease, and different mechanisms have been proposed. The authors present a possible explanation of congestive heart failure in some cases of thyrotoxicosis. A 39 year-old woman with Graves' disease was hypermetabolic, in atrial fibrillation, and had signs of congestive heart failure. She had a loud murmur of mitral regurgitation, clinical cardiomegaly, accentuated pulmonic sound, and peripheral edema. Propranolol reduced the heart rate to 60 beats per minute, but the loud mitral regurgitation murmur persisted. Echocardiographic and angiographic data were consistent with moderate to severe mitral regurgitation, serious enough to consider mitral valve replacement. As the patient's hyperthyroid state came under control, weight increased and the cardiac murmur resolved. After radioactive iodine treatment and the return to a eumetabolic state, an echocardiogram revealed only trace mitral regurgitation, with near normal left ventricular function and pulmonary arterial systolic pressures. These findings were confirmed by subsequent cardiac catheterization. The authors believe that mitral regurgitation, perhaps secondary to intrinsic papillary muscle dysfunction from hyperthyroidism, was the major cause of reversible congestive heart failure in this case. Valvular disease may play a more substantive role in thyrotoxic heart disease than previously recognized.

Для цитирования: Cavros N G, Old W D, Castro F D, Estep H L. Case report: reversible mitral regurgitation and congestive heart failure complicating thyrotoxicosis.. The American journal of the medical sciences. 1996. DOI: 10.1097/00000441-199603000-00007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.